© Copyright 1997 by Dataton AB, Sweden. Specifications are subject to change without prior notice. Document reference no. 3700/<None>–57
WITH SMARTPAX
If you need to connect a device to
SMARTPAX for controlling or sensing
purposes and there is no standard
smartlink available, use AUXILIARY
CABLE. The SMARTPAX pin-out and func-
tions are shown below.
WITH PAX
With PAX you have access to two relays,
designated W Aux and Y Aux. These
can handle 24V 1A. If AUXILIARY
CABLE is used to connect these relays to
external power relays or other inductive
loads, the included varistors must be
connected in parallel with the W Aux
and Y Aux relays.
WITH TRANSPAX
The
TAPE
connector on TRANSPAX may
be used for controlling most analog,
open-reel tape recorders. If no suitable
standard cable is available, use AUXIL-
IARY CABLE. TRANSPAX pin-out and
functions are shown below.
2 Red
3 Orange
4 Yellow
5 Green
8 Grey
S In
1 Brown
9 Black
SMARTP
A
X
Com In
S Out
RTS/Clock
Com Out
+12V
CTS
Y Aux
2 Red
3 Orange
4 Yellow
5 Green
7 Violet
1 Brown
W Sense
Y Sense
AX
P
W Aux
6 Blue
3 Orange
4 Yellow
8 Grey
9 Black
Stop
2 Red
5 Green
1 Brown
7 Violet
Sensor
AX
TRANSP
Rewind
Forward
Record
Pause
Play
+
–
+
NOTE
If you are not sure how to make the connection, get in touch with your Dataton dealer
or the Dataton support team at e-mail: [email protected] for more information.
Product sheets 970520 97-05-23 17.03 Page 57