120 20170-204a
Paragon
PD
Technical Manual
34
-
The EPROM and DIP switches locations are identical in both receiver and exciter modules (refer to
Figure 18 - Channel Selection via internal DIP switches
6.2 Series I 800MHz Radio Tuning
This section covers some basic tuning and verification for the 800 MHz Series I base station modules.
Note:
Usually, this section is not done unless called for in section 6.1 “Series I - Radio Programming”
or in Table 10 “Checklist B”.
6.2.1 Test
Equipment
You will need the following test equipment:
-
Digital multimeter and probes (e.g. Fluke 77)
-
Digital or analog calibrated Oscilloscope (X1, X2 selectable)
-
Calibrated COM-120B (with .001ppm TCXO and 30kHz IF options)
-
3 feet long double shielded N-M to BNC-M cable (RG-214 or RG-223)
-
2x 'BNC' to 'N' type adapters (e.g. Amphenol, Greenpar).
-
Bird RF power meter with 150W / 50 ohm dummy load (optional)
-
1x Torx screwdriver #10
-
Pozidriv screwdriver #1 & #2
-
1x six-inch adjustable wrench
-
RF tuning/trimming tools.
-
Extender Rail Kit for Series II chassis (T800-13-0000)
-
1x 6" coax cable N-M to BNC-M (provided with Paragon
PD
to connect the exciter and PA)
1
2
3
4
5
6
7
8
O
F
F
Binary Value
1
2
4
8
16
32
64
ON for 27C16 EPROM
OFF for 27C64 EPROM
(Always leave OFF)