Adjustments and Maintenance
2-10
Step
Action
Displayed Message
Comment(s)
11
Complete a table (see below)
using new measurements, as
follows:
(A) Raise the Printhead
Assembly. Place the label over
the Media Sensor, then lower
and latch the Printhead
Assembly. Record the sensor
reading as P.
(B) Raise the Printhead
Assembly. Place the liner,
notch, or mark over the Media
Sensor, then lower and latch
the Printhead Assembly.
Record the sensor reading as
G (or M).
(C) Raise the Printhead
Assembly. Remove all media
from the Media Sensor, then
lower and latch the Printhead
Assembly. Record the sensor
reading as E.
TRAN SENSOR GAIN
(0 - 31)
YYY
08
Where YYY is a numerical
value representing the current
sensor reading.
The re-sampled values may
differ from those previously
recorded. This is normal; do
not readjust the Media
Sensor.
Gain
Number
P
(paper)
G or M
(gap or mark)
E
(empty)
08
185
35
11