H-Class
65
Communications (continued)
Menu Item
Details
HEAT COMMAND
Determines how host Heat commands are handled,
where:
ENABLED
Processes software commands normally.
DISABLED
Controls Heat via the menu setting; see Section 4.2.2.
SPEED COMMANDS
Determines how host Print, Feed, Reverse, and Slew
commands are handled, where:
ENABLED
Processes software commands normally.
DISABLED
Controls speeds via the menu setting; see Section
4.2.2.
TOF SENSING COMMANDS
Determines how host Gap, Continuous, and Reflective
commands are handled, where:
ENABLED
Processes software commands normally.
DISABLED
Controls the Sensor Type via the menu setting; see
Section 4.2.2.
SYMBOL SET COMMAND
Determines how host Single and Double Symbol Set
commands are handled, where:
ENABLED
Processes software commands normally.
DISABLED
Controls Symbol Set selection via the menu setting;
see Section 4.2.4.
CNTRL-CODES (DATA)
Determines how host Control Codes are handled,
where:
ENABLED
Processes software commands normally.
DISABLED
Controls Control Codes via the menu setting; see
Section 4.2.4.
STX-V SW SETTINGS
Determines how a host option-enable command is
handled, where:
ENABLED
Processes the software command normally.
DISABLED
Controls <STX>V via menu settings; see Section
4.2.3.
Summary of Contents for H-4212
Page 1: ...Operator s Manual ...
Page 2: ......
Page 5: ......
Page 40: ...30 H Class ...
Page 84: ...74 H Class ...
Page 144: ...134 H Class ...
Page 148: ...138 H Class ...
Page 156: ...146 H Class ...
Page 160: ...150 H Class Network Status page TCP IP Configuration page ...
Page 162: ...152 H Class ...
Page 163: ...H Class 153 Printer Options Communications and Diagnostics pages ...
Page 164: ...154 H Class Network Print Options page ...
Page 165: ...H Class 155 Reset Network Parameters page Change Password page ...
Page 166: ...156 H Class ...
Page 180: ...170 H Class ...
Page 186: ...176 H Class ...