Extended System-Level Command Functions
62
Class Series Programmer’s Manual
<STX>Kc
Parameter Overviews
(AL) Alignment Length
– This command, critical for small labels when ‘Label Alignment’ is set
to ‘Yes,’ allows a length (measured from leading edge to leading edge of two successive labels)
to be entered. The measured length must be provided to the nearest hundredth of an inch. For
very small labels, errors of 0.01” can result in noticeable print variations on the labels between
the media sensor and the print head. The number of labels that can be fit between the Media
Sensor and the print head will magnify any error in label alignment length. Errors in measurement
are more favorable on the low side rather than the high side.
Non-Display printers only: The printer will verify the label position using the provided
Alignment Length before printing the first label after power-up.
(AS) Single Byte Symbol Set –
This command allows for a default single-byte symbol set. See
<STX>y
or
ySxx
for command details
.
(BA) Backup After Print –
This command determines the timing of the label back up positioning
when the present distance is set and the GPIO option or Present Sensor option (including Peel and
Present) is enabled. When enabled, the printer immediately backs up the label after the applicator-
issued start of print signal is received or the label is removed, resulting in faster throughput. If
disabled, the printer will not initiate repositioning until the next label is ready to print (may help
prevent the curling of the label edge).
(BD) Backup Delay –
This command sets a time delay for the retraction of a presented label in
one-fiftieth (1/50) of a second increments.
(BL) Backup Label –
This command determines the timing of reverse label motion when the I &
W-Class GPIO option is installed and enabled; see Appendix J for signal details.
(BP) British Pound –
This command, when enabled, will automatically switch from the Number
symbol (#) found at 0x23 (default PC-850 Multilingual Symbol Set) to the British Pound symbol
(£) at 0x9C.
(BS or bS) Backup Speed –
This command controls the rate of label movement during backup
positioning for start of print, cutting or present distance; see Appendix C for available speed
ranges.
Summary of Contents for A-Class A-4310
Page 2: ......
Page 4: ......
Page 15: ...xi Appendix V 281 Bar Code Symbology Information Resources 281 Glossary 283...
Page 16: ...xii...
Page 30: ...Immediate Command Functions 14 Class Series Programmer s Manual...
Page 52: ...System Level Command Functions 36 Class Series Programmer s Manual...
Page 144: ...Label Formatting Command Functions 128 Class Series Programmer s Manual...
Page 162: ...Generating Label Formats 146 Class Series Programmer s Manual...
Page 182: ...Appendix D Reset Codes 166 Class Series Programmer s Manual...
Page 192: ...Appendix E Single Byte Symbol Sets 176 Class Series Programmer s Manual...
Page 236: ...Appendix G Barcode Details 220 Class Series Programmer s Manual...
Page 242: ...Appendix I Symbol Sets and Character Maps 226 Class Series Programmer s Manual...
Page 272: ...Appendix P UPC A and EAN 13 256 Class Series Programmer s Manual...
Page 282: ...Appendix R Plug and Play IDs 266 Class Series Programmer s Manual...
Page 296: ...Appendix U WiFi Region Country Codes 280 Class Series Programmer s Manual...
Page 302: ...Glossary 286 Class Series Programmer s Manual...