Extended System-Level Command Functions
Class Series Programmer’s Manual
67
(FH) Fault Handling –
This command determines the level of user intervention and the
disposition of the label being printed when a fault condition (ribbon out, media out, etc.) occurs.
Value Units / Interpretation
Selection / Definition
Interaction Level,
where:
0 = No Reprint;
In No Reprint Mode (0), printing stops and a fault message is
displayed. After the problem is corrected, the FEED Key must be
pressed to clear the fault. The label in process is
not
reprinted.
1 = Standard;
and,
In Standard Mode (1), printing stops and a fault message is
displayed. After the problem is corrected, the FEED Key must be
pressed to clear the fault. The label in process is reprinted.
L
2 = Void and Retry
In Void and Retry Mode (2), depending upon the RETRY COUNT,
one of the following actions when faulted:
•
If the Retry Count has not been exceeded, ‘VOID’ is printed on
the label in process and reprinting occurs automatically;
•
If the Retry Count has been exceeded, printing stops and a fault
message is displayed. After the problem is corrected, the FEED
Key must be pressed to clear the fault. The label in process is
reprinted; or,
•
If the CANCEL Key is pressed, the operator now has the option
of canceling the reprint:
To allow the reprint, press the ESCAPE Key or to cancel the
reprint, press the ENTER Key (the operator now has the option
of canceling the entire label batch by pressing the ENTER Key
again
.)
Note:
VOID will not be printed when insufficient text space exists (see
VOID DISTANCE, below) or if the fault occurs after the label reaches its
Present Distance at, or above, the TOF).
D
Void Distance
(.10 - 2.00)
Sets the distance
(
.10 - 2.00
)
to backup the faulted label to print
‘VOID’ on its trailing edge, which also indirectly establishes the
font size of the void message.
R
Retry Count
(0 – 3)
Only used with the RFIF or Scanner option installed and operating.
Establishes the number of times (0 – 3) the printer will attempt to
reprint a label. If the last label printed in this count has been
voided, the printer will stop and display a fault message.
B
Enable / disable
Y,N
Retract from presented distance prior to feed-clear motion. This
option is intended for use with applicator equipment that may
require certain GPIO signals for proper operation.
Table 5-2: Fault Handling Command
Example:
<STX>KcFHD112<CR>
(The example configures the printer to back up and print a one-inch “VOID” message on a
label when a fault is detected; if two successive faults occur during the printing of that label
then the FEED Key must be pressed to clear the fault.)
Summary of Contents for A-Class A-4310
Page 2: ......
Page 4: ......
Page 15: ...xi Appendix V 281 Bar Code Symbology Information Resources 281 Glossary 283...
Page 16: ...xii...
Page 30: ...Immediate Command Functions 14 Class Series Programmer s Manual...
Page 52: ...System Level Command Functions 36 Class Series Programmer s Manual...
Page 144: ...Label Formatting Command Functions 128 Class Series Programmer s Manual...
Page 162: ...Generating Label Formats 146 Class Series Programmer s Manual...
Page 182: ...Appendix D Reset Codes 166 Class Series Programmer s Manual...
Page 192: ...Appendix E Single Byte Symbol Sets 176 Class Series Programmer s Manual...
Page 236: ...Appendix G Barcode Details 220 Class Series Programmer s Manual...
Page 242: ...Appendix I Symbol Sets and Character Maps 226 Class Series Programmer s Manual...
Page 272: ...Appendix P UPC A and EAN 13 256 Class Series Programmer s Manual...
Page 282: ...Appendix R Plug and Play IDs 266 Class Series Programmer s Manual...
Page 296: ...Appendix U WiFi Region Country Codes 280 Class Series Programmer s Manual...
Page 302: ...Glossary 286 Class Series Programmer s Manual...