Extended System-Level Command Functions
42
Class Series Programmer’s Manual
STX Kc
Configuration Set
This command specifies the Power-up Configuration parameter values for the printer and is
equivalent to using other system commands followed by the
<SOH>U
.
This command is intended
for easily configuring a custom setup, but NOT for dynamic configuration changes.
Configuration commands are examined for differences relative to the current configuration; the
command has no impact when there are no differences.
Display-equipped models will reset upon
completion of a command stream containing parameter value changes; non-display models perform
this reset only for certain functions, such as memory allocation. In any case, no commands should be
sent to the printer until this reset is complete. These are some highlights of the command:
These parameter values are equivalent to changing the respective menu settings and do not affect
the factory default settings of the printer.
If separated by a semi-colon (;), multiple parameter values may be sent in a single command
stream; see sample below.
All values are stored in Flash memory and remain in effect until new values are received or until
factory defaults are restored.
If system commands are sent that override the Power-up Configuration value(s), the Power-up
Configuration value(s) will be restored the next time the printer is powered ‘On’ or reset.
These parameters are the same as those found in the Setup Menu (non-display models), or as
those found in the Menu System (display-equipped models). The respective functions are
documented in the appropriate
Operator’s
or
Maintenance Manual
. Not all commands are
effective on all Class printers.
Note:
Illegal or out of range parameter values may have unpredictable results. In addition, Media sensing
scaling values, TOF Bias, etc. may not be effective on other printers of the same type due to
hardware tolerances.
Syntax:
<STX>Kcaa
1
val
1
[;aa
I
val
I
][;aa
n
val
n
]<CR>
Where:
aa
1,
aa
I
, aa
n
- Are two letter parameter names.
val
1,
val
I,
val
n
- Are parameter values, with ranges appropriate for
the associated parameter.
Sample:
<STX>KcPA120;CL600;STC<CR>
The sample sets the Present Adjust to 120 dots, the Continuous Label Length to 6 inches, and the
Sensor Type to Continuous.
The following table (constructed alphabetically by parameter name) summarizes the different
Configuration Set command parameters, value ranges, valid printer models, and menu item and
command equivalents (where applicable). If no command equivalent is given, or where general
clarification is necessary for the command, descriptions (listed alphabetically by parameter
pneumonic) immediately follow this table.
Summary of Contents for A-Class A-4310
Page 2: ......
Page 4: ......
Page 15: ...xi Appendix V 281 Bar Code Symbology Information Resources 281 Glossary 283...
Page 16: ...xii...
Page 30: ...Immediate Command Functions 14 Class Series Programmer s Manual...
Page 52: ...System Level Command Functions 36 Class Series Programmer s Manual...
Page 144: ...Label Formatting Command Functions 128 Class Series Programmer s Manual...
Page 162: ...Generating Label Formats 146 Class Series Programmer s Manual...
Page 182: ...Appendix D Reset Codes 166 Class Series Programmer s Manual...
Page 192: ...Appendix E Single Byte Symbol Sets 176 Class Series Programmer s Manual...
Page 236: ...Appendix G Barcode Details 220 Class Series Programmer s Manual...
Page 242: ...Appendix I Symbol Sets and Character Maps 226 Class Series Programmer s Manual...
Page 272: ...Appendix P UPC A and EAN 13 256 Class Series Programmer s Manual...
Page 282: ...Appendix R Plug and Play IDs 266 Class Series Programmer s Manual...
Page 296: ...Appendix U WiFi Region Country Codes 280 Class Series Programmer s Manual...
Page 302: ...Glossary 286 Class Series Programmer s Manual...