COMPONENT SPECIFICATION
C00525
C00525
C00525
C00525
- 3 -
2.1. FINISH CODES (CONTINUED)
2.1.2. Contact Finish:
3. RATINGS
All materials are listed on individual drawings.
3.1. LOW-FREQUENCY SIGNAL CONNECTORS
3.1.1. Electrical characteristics
Current – per individual contact at an ambient temperature of 25°C ................................... 3.3A max
(When only one contact per connector is electrically loaded)
Current – per individual contact at an ambient temperature of 85°C ................................... 2.6A max
(When only one contact per connector is electrically loaded)
Current – per contact through all contacts at an ambient temperature of 25°C................... 3.0A max
Current – per contact through all contacts at an ambient temperature of 85°C .................. 2.2A max
Working Voltage (at 1013mbar, sea level) ..................................................................800V DC or AC Peak
Voltage Proof (at 1013mbar, sea level) .......................................................................1200V DC or AC Peak
Contact resistance (initial) ...................................................................................................... 20mΩ max
Contact resistance (after conditioning) .................................................................................. 25mΩ max
Insulation resistance (initial) ................................................................................................... 1,000 MΩ min
Insulation resistance (hot after conditioning) ........................................................................ 100 MΩ min
Creepage path contact-to-contact .......................................................................................... 0.35mm min
Air gap contact-to-contact ...................................................................................................... 0.35mm min
3.1.2. Environmental characteristics
Environmental classification.............................................................................-55/+125/56 Days at 95% RH
Low air pressure severity when only one contact is electrically loaded.......300 mbar (9,144M/30,000ft)*
Vibration severity ................................... 10Hz to 2000Hz over 0.75mm at 98m/s² (10G), duration 6 hours
Vibration severity ................................... 10Hz to 81.73Hz @ 1.5mm peak to peak, 57.55Hz to 2000Hz
@ 20g. duration 2 hours
Bump severity ....................................................................................... 390m/s² (40G), 4000 ±10 bumps
Shock severity ....................................................................................... 981m/s² (100G) for 6ms
Finish Code
Finish Code
Finish Code
Finish Code
01
01
01
01
05
05
05
05
22
22
22
22
42
42
42
42
Male PC Tail
--
Gold all over
Gold on Contact area
Tin /Lead on tail
Gold on Contact area
100% Tin on tail
Male Crimp
--
Gold all over
--
--
Female PC
Tail
Gold on Contact area
Tin /Lead on tail
Gold all over
--
Gold on Contact area
100% Tin on tail
Female
Crimp
--
Gold clip,
Gold shell
--
Gold clip,
Gold shell