60
VISUALIZATION
STATUS
DESCRIPTION
ACTION
FAILURE LOCKOUT
(NOT RECOVERABLE)
MICROCONTROLLER
FAILURE, OSSDS OFF
USER MUST TURN OFF/ON ESPE.
IF THE PROBLEM PERSISTS USER
MUST CONTACT DATALOGIC
TECHNICAL SUPPORT.
FAILURE LOCKOUT
(RECOVERABLE)
OPTICAL FAILURE, OSSDS
OFF
USER MUST ACTIVATE RESET
LINE. IF ESPE DOES NOT RESET
USER MUST CONTACT DATALOGIC
TECHNICAL SUPPORT.
FAILURE LOCKOUT
(RECOVERABLE)
EDM FAILURE, OSSDS OFF
USER MUST CHECK EDM ENABLE
LINE OR DIP-SWITCHES, EDM LINE,
EXTERNAL SWITCHING DEVICE
AND ACTIVATE RESET LINE. IF
ESPE DOES NOT RESET USER
MUST CONTACT DATALOGIC
TECHNICAL SUPPORT.
FAILURE LOCKOUT
(NOT RECOVERABLE)
OVERRIDE CONNECTION
FAILURE, OSSDS OFF
USER MUST CHECK OVERRIDE
LINES CONNECTION AND TURN
OFF/ON ESPE. IF THE PROBLEM
PERSISTS USER MUST CONTACT
DATALOGIC TECHNICAL SUPPORT.
SAFE
OVERRIDE SEQUENCE
FAILURE, OSSDS OFF
USER MUST CHECK OVERRIDE
LINES ACTIVATION SEQUENCE
TIMINGS AND REPEAT OVERRIDE
SEQUENCE. IF THE PROBLEM
PERSISTS USER MUST CONTACT
DATALOGIC TECHNICAL SUPPORT.
FAILURE LOCKOUT
(NOT RECOVERABLE)
DIP SWITCH FAILURE,
OSSDS OFF
USER MUST CHECK DIP-SWITCH
CONFIGURATION AND TURN
OFF/ON ESPE. IF THE PROBLEM
PERSISTS USER MUST CONTACT
DATALOGIC TECHNICAL SUPPORT.