SG BODY REFLECTOR MUTING
43
•
Application with 2 optoelectronic sensors: parallel-beam configuration
The solution is suitable for applications requiring unidirectional movements of objects.
For correct functioning, position the dip-sw
itches to select “L” configuration.
The reset of normal Muting functioning is obtained at a DMoff distance from sensor A.
A
B
SG
Muting sensors connection:
A contact
B contact
24 Vdc
M12-5 poles connector
Pin 2
MUTING 1
Pin 4
MUTING 2
L
V=cost.
d1
D
Moff
Symbol
Unit
Formula
Min
Typ
Max
Description
D
1
cm
= V * t
AB
* 100
0.1
Interaxis between sensor A and sensor B
D
Moff
cm
Compulsory condition
33
Distance from sensor A at which the Muting function is
deactivated and the light curtain returns to normal
functioning
t
AB
sec
Compulsory condition
0.01
4
Activation time of the second sensor after first sensor
activation (A
B)
t
Moff
sec
= D
Moff
/ V
0.132
(at max. suggested
speed)
8
Time period, referred to sensor A, after which the Muting
function is deactivated and the light curtain returns to
normal functioning
D
OA
cm
= D
Moff
49.5
Distance to respect between adjacent objects to obtain
the correct Muting functioning
L
cm
d
1
Object dimension to activate the Muting function passing
between the sensors
V
cm/sec
= d
1
/ t
AB
4.125
250
(suggested)
Object speed to activate the Muting function passing
between the sensors
Summary of Contents for SG4-RB2-050-OO-W
Page 1: ......
Page 3: ......
Page 7: ......
Page 73: ...66 SG4 RB2 3L SG4 RDB2 3L...
Page 74: ...SG BODY REFLECTOR MUTING 67 SG4 RB2 3T SG4 RDB2 3T...
Page 91: ...84 ACTIVE PASSIVE...
Page 92: ...SG BODY REFLECTOR MUTING 85 ACTIVE PASSIVE...
Page 95: ...88...