44
•
Application with L arm
A
B
SG
Muting sensors connector:
A contact
B contact
24 Vdc
M12-5 poles connector
Pin 2
MUTING 1
Pin 4
MUTING 2
L
V=cost.
d1
D
Moff
The L-configured solution with integrated Muting facilitates sensor installation and suits applications
with unidirectional object passage.
For correct functioning, position the dip-
switches to select “L” configuration.
The reset of normal Muting functioning is obtained at a DMoff distance from sensor A.
Symbol
Unit
Formula
Min
Typ
Max
Description
d
1
cm
Compulsory
condition
16.5
Interaxis between sensor A and sensor B
D
Moff
cm
Compulsory
condition
33
Distance from sensor A at which the Muting function is
deactivated and the light curtain returns to normal
functioning
t
AB
sec
Compulsory
condition
0.01
4
Activation time of the second sensor after first sensor
activation (A
B)
t
Moff
sec
= D
Moff
/ V
0.132
(at max. suggested
speed)
8
Time period, referred to sensor A after which the
Muting function is deactivated and the light curtain
returns to normal functioning
D
OA
cm
= D
Moff
49.5
Distance to respect between adjacent objects to obtain
the correct Muting functioning
L
cm
d
1
Object dimension to activate the Muting function
passing between the sensors
V
cm/sec
= d
1
/ t
AB
4.125
250
(suggested)
Object speed to activate the Muting function passing
between the sensors
Summary of Contents for SG4-RB2-050-OO-W