Enter/Exit Programming Mode
258
RIDA™ DBT6400
BATCH FEATURES
Batch Mode
This option specifies whether to store labels in the handheld while disconnected from
the base. Options are as follows:
• Disabled — The handheld will not store/batch labels.
• Automatic — The handheld will store labels in its internal memory when the
handheld goes out of range and is disconnected from the remote device. When
the connection is restored, the labels are immediately transmitted to the remote
device.
• Manual — The handheld will always store labels to Flash memory. The user must
manually send the stored labels to the remote device using a special "batch send"
label.
DEFAULT
$CBTBM00(CR)
Batch Mode = Disabled
$CBTBM01(CR)
Batch Mode = Automatic
$CBTBM02(CR)
Batch Mode = Manual
Send Batch
When the scanner is configured in Manual Batch Mode, use the following bar code to
initiate sending of labels stored in batch memory.
BatchSend
Send Batch
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunc-
tion with this bar code.