Enter/Exit Programming Mode
Maxicode
206
RIDA™ DBT6400
Maxicode Length Control
This feature specifies either variable length decoding or fixed length decoding
for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CMXLC00(CR)
Maxicode Length Control = Variable Length
$CMXLC01(CR)
Maxicode Length Control = Fixed Length
Maxicode
Set Length 1
Specifies one of the bar code lengths for
Maxicode Length Control on page 206
Length 1 is the minimum label length if in
Variable Length
Mode, or the first
fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0145
characters in increments of 0001 (pad with zeroes).
See
for detailed instructions on setting this feature.
$CMXL1
Select Maxicode Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followed by the digits from the Alphanumeric char-
acters in
representing your
desired character(s). End by scanning the ENTER/EXIT
bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
0001 = Length 1 is 1 Character
DEFAULT
Summary of Contents for RIDA DBT6400
Page 26: ...Setup 18 RIDA DBT6400 NOTES...
Page 70: ...Enter Exit Programming Mode USB Keyboard Speed 62 RIDA DBT6400 NOTES...
Page 112: ...Reading Parameters 104 RIDA DBT6400 NOTES...
Page 200: ...Enter Exit Programming Mode BC412 192 RIDA DBT6400 NOTES...
Page 232: ...Symbology Selection 224 RIDA DBT6400 NOTES...
Page 278: ...Enter Exit Programming Mode 270 RIDA DBT6400 NOTES...
Page 286: ...Technical Specifications 278 RIDA DBT6400 NOTES...
Page 298: ...Standard Defaults 290 RIDA DBT6400 NOTES...