1D Symbologies
Enter/Exit Programming Mode
Product Reference Guide
153
Codabar
The following options apply to the Codabar symbology.
Codabar Enable/Disable
When disabled, the scanner will not read Codabar bar codes.
DEFAULT
Codabar = Disable
Codabar = Enable
Codabar Check Character Calculation
Enable this option to enables/disables calculation and verification of an
optional Codabar check character. When disabled, any check characters in the
label are treated as data character
DEFAULT
Codabar Check Character Calculation = Don’t Calculate
Codabar Check Character Calculation = Enable AIM standard
check char.
Codabar Check Character Calculation = Enable Modulo 10
check char.
s.
$CCBEN00
$CCBEN01
$CCBCC00
$CCBCC01
$CCBCC02
Summary of Contents for RIDA DBT6400