14
QuickScan™ I QM21X1 / QBT21X1
Replacing the Battery Pack
1. Using a coin or screwdriver, unscrew the captive screw located on the bot-
tom of the scanner handle until the battery pack is disengaged.
The battery pack will rise slightly in the rear, pushed by the contact springs.
2. Extract the battery pack by slightly rotating the pack and pulling away
from the reader.
To mount the new battery pack reverse the process:
1. Insert the top of the new pack inside the reader’s handle.
2. Rotate the battery pack downward while pressing the bottom side of the
battery pack (to seat securely into the contact springs) so that the edges of
the pack and the handle board are aligned, while securing the captive
screw in the bottom of the handle.
NOTE
Before proceeding, read “Battery Safety” on the preceding pages. Datalogic recom-
mends annual replacement of rechargeable battery packs to ensure maximum perfor-
mance.
Captive
screw