SOFTWARE CONFIGURATION
46
Example
: to have a Data Packet composed of Code Data followed by the ISO/IEC 15415
code quality parameters (grade only) in parenthesis, separated by a comma and a space, the
Data Packet Format string must be the following:
Data Packet Format = %2 (%C, %E, %I, %K, %a, %m, %Q, %n)
The transmitted code quality parameters have the following format:
•
1 character for code quality parameters expressed as grade (i.e. A,B,C,D,F or P,F)
•
1 character for code quality parameters expressed as numeric value corresponding to a
grade (0,1,2,3,4).
•
4 numeric characters for code quality parameters expressed as percentage including dot
(example: 78%
→
0.78).
•
3 numeric characters for AS9132A Angle Of Distortion parameter (example: 3°
→
003).
When ISO/IEC 16022-18004
Status
parameter is enabled, the following code quality
parameters can be included in the Data Packet Format string:
•
%C ISO-IEC / AIM DPM Overall (Grade)
•
%D ISO-IEC / AIM DPM Overall (Value)
•
%E ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (grade)
•
%F ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (value)
•
%G ISO-IEC / AIM DPM Print Growth (grade)
•
%H ISO-IEC / AIM DPM Print Growth (value)
•
%I ISO-IEC / AIM DPM Axial Non Uniformity (grade)
•
%J ISO-IEC / AIM DPM Axial Non Uniformity (value)
•
%K ISO-IEC / AIM DPM Unused ECC (grade)
ISO-IEC / AIM DPM Unused ECC (value)
•
%L
When ISO/IEC 15415
Status
parameter is enabled, the following code quality parameters
can be included in the Data Packet Format string:
•
%C ISO-IEC / AIM DPM Overall (Grade)
•
%D ISO-IEC / AIM DPM Overall (Value)
•
%E ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (grade)
•
%F ISO-IEC Symbol Contrast / AIM DPM Cell Contrast (value)
•
%H ISO-IEC / AIM DPM Print Growth (value)
•
%I ISO-IEC / AIM DPM Axial Non Uniformity (grade)
•
%J ISO-IEC / AIM DPM Axial Non Uniformity (value)
•
%K ISO-IEC / AIM DPM Unused ECC (grade)
•
%L ISO-IEC / AIM DPM Unused ECC (value)
•
%a ISO-IEC / AIM DPM Decode (Grade)
•
%Q ISO-IEC Modulation / AIM DPM Cell Modulation (grade)
•
%R ISO-IEC Modulation / AIM DPM Cell Modulation (value)
•
%m ISO-IEC / AIM DPM Fixed Pattern Damage (grade)
•
%W ISO-IEC / AIM DPM Fixed Pattern Damage (value)
•
%n ISO-IEC / AIM DPM Grid Non Uniformity (grade)
•
%X ISO-IEC / AIM DPM Grid Non Uniformity (value)