SOFTWARE CONFIGURATION
46
5.3.3 Send
Configuration
Options
The device parameters are divided into two main classes,
Configuration
and
Environmental
which are effected differently by the Send Configuration and Send Default
Configuration commands.
Configuration Parameters regard parameters that are specific to the device. These
parameters are influenced by the Send Configuration and Send Default Configuration
commands, that is they are overwritten by these commands.
The same parameters are modified by the following "Send Configuration with Options" and
"Send Default Configuration with Options" dialogs from the Device Menu:
Figure 29 - Send Configuration Options
Environmental Parameters regard the device Identity and Position in a Network (ID-NET™,
Master/Slave RS232, MUX32, Ethernet) and are not influenced by the "Send Default
Configuration" and "Send Configuration" commands.
This allows individual devices to be configured differently without affecting their recognized
position in the network.
57