5.4.2 ISO/IEC 15416 Verification Setup
Allows to configure lighting and camera settings to comply with ISO/IEC 15416 optical
requirements for 1D symbol verification.
ISO-IEC 15415-15416 SETUP
Aperture Mode
Allows configuration of the Aperture parameter according to the ISO-IEC 15415 and ISO-IEC
15416 international standards. The possible selections are:
•
Automatic
: the physical size of the virtual aperture applied to the captured symbol image
is automatically calculated by the verification software.
•
Custom
: allows specifying the physical size of the virtual aperture applied to the captured
symbol image.
Aperture (mils)
Sets the physical size of the virtual aperture applied to the captured symbol image by the
verification software.
Angle
Sets the incidence angle at which the symbol is illuminated by the lighting system during the
verification process.
Light Wavelength (nm)
Sets the wavelength in nanometres of the LED illumination directed at the symbol during the
verification process. The possible selections are:
•
White
•
660
•
760
ISO-IEC 15416
Status
Enables/disables symbol verification according to the ISO-IEC 15416 international standard
for Code 128, Code 39, Interleaved 2 of 5, Codabar, Code 93, EAN-8/EAN-13, UPC-A/UPC-
E symbologies.
Grade Type
Allows selecting the appearance of the ISO-IEC 15416 verification output. The possible
selections are:
•
10 Scans
: supplies Scan Reflectance Profile Grades for each quality parameter on each
of 10 code scans.
•
Media
: supplies the mathematical average Scan Reflectance Profile Grade for each
quality parameter over 10 code scans.
•
Media & 10 Scans
: supplies Scan Reflectance Profile Grades for each quality parameter
on each of 10 code scans plus the mathematical average.