MATRIX 400™ CODE QUALITY VERIFIER SOLUTION
1
CBX100/CBX500 PINOUT FOR MATRIX 400™
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this
pinout when the Matrix 400™ reader is connected by means of the CBX100/CBX500:
CBX100/500 Terminal Block Connectors
Input Power
Vdc
Power Supply Input V
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
Inputs
+V
Power Source – External Trigger
I1A
External Trigger A (polarity insensitive)
I1B
External Trigger B (polarity insensitive)
-V
Power Reference – External Trigger
+V
Power Source – Inputs
I2A
Input 2 A (polarity insensitive)
I2B
Input 2 B (polarity insensitive)
-V
Power Reference – Inputs
Outputs
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
Auxiliary Interface
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
ID-NET™
REF Network
Reference
ID+
ID-NET™ n
ID-
ID-NET™ network -
Shield
Network Cable Shield
Main Interface
RS232
RS485
Full-Duplex
RS485
Half-Duplex
TX
TX+
RTX+
RX
*
RX+
RTS
TX-
RTX-
CTS
*
RX-
SGND
SGND
SGND
(*) Do not leave floating, refer to Matrix 400™ Reference Manual for connection details.
CAUTION
Do not connect GND, SGND and REF to different (external) ground
references. GND, SGND and REF are internally connected through
filtering circuitry which can be permanently damaged if subjected to
voltage drops over 0.8 Vdc.