READING FEATURES
95
7
7 READING FEATURES
MODELS
Focus
Distance
mm (in)
Field of View
(1)
mm (in)
PPI
(2)
Typ.
Linear and
Stacked
Code
Resolution
mm (mils)
2D Code Resolution
mm (mils)
Reading
Distance
(3)
mm (in)
min.
max.
214-xxx UHD
30
(1.18)
16.5 10.5
(0.65 0.41)
1150
0.063 (2.5)
Max.
0.076 (3)
28 (1.10)
32 (1.26)
Typ.
0.13 (5)
23 (0.91)
38 (1.50)
211-xxx NEAR
45
(1.77)
35 22
(1.38 0.87)
545
0.10 (4)
Max.
0.13 (5)
42 (1.65)
53 (2.08)
Typ.
0.19 (7.5)
36 (1.42)
61 (2.40)
212-xxx MEDIUM
65
(2.56)
50 32
(1.97 1.26)
380
0.15 (6)
Max.
0.19 (7.5)
54 (2.13)
90 (3.54)
Typ.
0.25 (10)
47 (1.85)
101 (3.97)
213-xxx FAR
105
(4.13)
80 50
(3.15 1.97)
238
0.20 (8)
Max.
0.25 (10)
85 (3.35)
135 (5.31)
Typ.
0.38 (15)
70 (2.76)
192 (7.55)
(1)
@ Focus Distance
(2)
Pixels per inch @ Focus Distance
(3)
Measurement Conditions:
Test Chart: provided with the reader
Still code at the center of the FOV
Code Symbology: Data Matrix ECC 200
Tilt Angle: 45°
Skew Angle: 15°
Image Processing Mode =
Advanced Code Setting
Module Size (mils) equal to the resolution of the code to read
Image Processing Self Tuning =
Enabled
Image Processing Self Tuning Mode =
Code Contrast Levels Only *
Image Acquisition Self Tuning =
Enabled
(for 213-xxx models only)
* This parameter setting can increase the image processing time.
All distances are measured from the reading window to the code surface.
Depending on the code resolution, symbology and number of characters in the code, the
Reading Area can be different from the FOV.
Summary of Contents for Matrix 210
Page 1: ...MATRIX 210 Reference Manual...
Page 142: ...www datalogic com...