452
Magellan™ 9300i / 9400i Scanners
ScaleSentry / Scale Service Button
The ScaleSentry / Scale Service Button is used for multiple functions.
Table 4. ScaleSentry / Scale Service Button Functions
Deactivate
EAS System
When Failed
Deactivation (Tri-color) LED is
flashing slowly Red. FRU Status
LED displays error code nine (9)
Upon initiating this state
(pressing EAS Button for 3
seconds): 3 high-pitched
beeps
Upon EAS malfunction/failure,
scanning function can continue
independent of EAS if the EAS
button is held for 3 seconds.
DECOUPLED MODE
Deactivation
Indicated
Deactivation (Tri-color) LED
flashes Red.
EAS Beep OFF
An EAS tag has been success-
fully deactivated.
HYBRID MODE
Deactivation
Indicated
Deactivation (Tri-color) LED
flashes Red, then Orange, then
returns to Green.
High frequency beep
An EAS tag has been success-
fully deactivated.
a. Additionally, the FRU LED (Health & Status Indicator located in the bottom of the optic cavity — visible through
the horizontal scan window) blinks the number ‘9’. If EAS deactivation fails to initiate, a low, error tone will be
sounded, and the FRU LED will display the error code ‘9’ steadily (without flashing).
b. Ticking sound will stop upon one of the following: 1) Manual EAS Deactivation Push Button is pressed and
released again, 2) EAS timer runs out, or 3) Following a successful EAS tag deactivation.
PRESS
DURATION
FUNCTION
COMMENT
Momentary
Override
If a ScaleSentry event is occurring, this will override the scale
sentry event. If no ScaleSentry event is occurring, this will acti-
vate the manual tare function of the scale.
4 Seconds
Scale
Diagnostics
Mode
a
This mode allows system support personnel to troubleshoot
problems with the scale. Momentarily press the Scale Zero But-
ton or cycle power to exit Scale Diagnostics Mode. See the topic,
Scale Error Reporting on page 67
section for more details.
8 Seconds
Resets Scanner
Only system support personnel should perform a reset.
Momentary while in Scale
Diagnostics Mode
Resets Scanner
A scanner reset can also be initiated by a momentary press of
this button while in Scale Diagnostics Mode.
a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to initiate this
function under normal circumstances.
Summary of Contents for Magellan 9300i
Page 1: ...Magellan 9300i 9400i Scanner and Scanner Scale with Imaging Technology Product Reference Guide...
Page 12: ...x Magellan 9300i 9400i Scanners NOTES...
Page 28: ...16 Magellan 9300i 9400i Scanners NOTES...
Page 60: ...48 Magellan 9300i 9400i Scanners NOTES...
Page 72: ...60 Magellan 9300i 9400i Scanners NOTES...
Page 92: ...80 Magellan 9300i 9400i Scanners Figure 46 EAS antenna EAS Antenna Calibration Switch Cover...
Page 104: ...92 Magellan 9300i 9400i Scanners NOTES...
Page 114: ...102 Magellan 9300i 9400i Scanners NOTES...
Page 136: ...Enter Exit Programming Mode Imaging and CSS Features 124 Magellan 9300i 9400i Scanners NOTES...
Page 214: ...202 Magellan 9300i 9400i Scanners NOTES...
Page 276: ...Enter Exit Programming Mode Interface Related Features 264 Magellan 9300i 9400i Scanners NOTES...
Page 292: ...Enter Exit Programming Mode Data Editing 280 Magellan 9300i 9400i Scanners NOTES...
Page 468: ...456 Magellan 9300i 9400i Scanners NOTES...
Page 472: ...460 Magellan 9300i 9400i Scanners NOTES...
Page 480: ...468 Magellan 9300i 9400i Scanners NOTES...
Page 482: ...470 Magellan 9300i 9400i Scanners NOTES...