Product Reference Guide
3-17
Gasketed Models
1. Remove the All Weighs™ Platter from the scanner as shown in
2. Turn the platter upside down on a clean, dry surface and remove
the two screws and two nuts shown in
a. Retain all
screws and nuts for later reinstallation.
3. Lift the edge of the retainer shown in
b and remove it
from the assembly.
4. Take note of how the gasket is seated, then gently peel it away
from the assembly as shown in
c. Retain the gasket for
reinstallation.
5. The window can now be removed (see
d). Carefully dis-
pose of any damaged glass.
6. While carefully holding it by its edges, tilt a new horizontal win-
dow fully into position as shown in
d.
7. Fit the gasket into its channel as shown in
c and press
around its entire perimeter to ensure it is fully seated.
8. Reinstall the retainer in the orientation shown in
aligning both holes with their studs.
9. Secure the retainer using the original two screws and two nuts as
shown in
10. Clean both sides of the new horizontal window using a paper
towel or lint free cleaning tissues dampened with a mild, water-
based glass cleaner. DO NOT use abrasive cleaners or pads.
Reinstall the platter. Gasketed horizontal window replacement is now
complete.
Summary of Contents for MAGELLAN 8500?
Page 1: ...Magellan 8500 Product Reference Guide...
Page 14: ...12 Magellan 8500 Scanner NOTES...
Page 66: ...2 36 Magellan 8500 Scanner NOTES...
Page 84: ...3 18 Magellan 8500 Scanner Figure 3 6 Removing Replacing the Gasketed DLC Window a b c d...
Page 89: ...Product Reference Guide 4 5 Figure 4 1 7 Segment LED Display 7 Segment Display Models vary...
Page 98: ...4 14 Magellan 8500 Scanner NOTES...
Page 420: ...D 2 Magellan 8500 Scanner NOTES...
Page 436: ...E 16 Magellan 8500 Scanner NOTES...
Page 452: ...F 16 Magellan 8500 Scanner NOTES...
Page 453: ...Product Reference Guide F 17 NOTES...
Page 454: ...F 18 Magellan 8500 Scanner NOTES...