background image

Long range Multi Reader  

AY-Z12 

Installation Guide 

 

May 2009 

 

 

Summary of Contents for AY-Z12

Page 1: ...Long range Multi Reader AY Z12 Installation Guide May 2009 ...

Page 2: ......

Page 3: ...f Contents 1 Introduction 3 2 Technical Specifications 5 3 Installation 6 3 1 The Installation Kit 6 3 2 Installing the AY Z12 Long Range Reader 6 4 Wiring Instructions 9 5 Operation Instructions 10 Appendix A Limited Warranty 11 Appendix B Technical Support 13 ...

Page 4: ...Reader is an RFID proximity card reader utilized with access control systems Figure 1 The AY Z12 Long Range Reader This Manual contains the following information Installation Wiring Instructions Operation Instructions Page 3 AY Z12 Installation Manual ...

Page 5: ...lled professionally This product has only one available channel Pursuant to FCC 15 21 54 FR 17714 Apr 25 1989 as amended at 68 FR 68545 Dec 9 2003 changes or modifications made to equipment which are not expressly approved by Rosslare Enterprises Ltd may void the user s authority to operate the equipment ...

Page 6: ...ent 30mA Maximum Cable Distance to Controller 500 ft 150 meters Card Read Distance Weigand 26 output format with a 23 6 60 cm maximum read range Environmental Characteristics Operating Temp Range 22 F to 145 F 30 C to 63 C Operating Humidity 0 95 non condensing Suitable for outdoor use IP54 Dimensions Height x Width x Depth 11 81 x 11 81 x 1 0 300mm x 300mm x 25 4 mm Weight 2 35 Lbs 1066g Measured...

Page 7: ...omprises of the following items that are to be used during the installation procedure One Installation Template Four pan head screws wall plugs One L shaped security screw tool Three Security screws 3 2 Installing the AY Z12 Long Range Reader AY Z12 Installation Manual Page 6 ...

Page 8: ...st be mounted with the appropriate screws not supplied as described in the template provided Installing the unit on metal surfaces will reduce the read range considerably to decrease the affect of the metal surface use Rosslare s MP Z02 Spacer sold separately as described in the image below for a max range of 43cm 17 inch Figure 3 Installing the unit with the MP Z02 spacer Page 7 AY Z12 Installati...

Page 9: ...ocation 3 Using the template as a guide drill the holes the size of which are indicated in the template to install the Reader or spacer onto the surface 4 Drill a 7 16 10mm hole for the cable In the event that you are installing the reader on metal place a grommet or electrical tape around the edge of the hole and use the MP Z02 spacer 5 Route the interface cable from the Reader to the Controller ...

Page 10: ...ple wire to the correct input on the Controller Reader Color Weigand Output 10 16 VDC Red DC Input Shield Ground Black Ground Data 1 White Data 1 Data 0 Green Data 0 LEDCTL Brown LED Control Tamper Purple Tamper 4 Trim and cover all unused conductors Note The individual wires from the Reader are color coded according the Wiegand standard When using a separate power supply for the Reader this suppl...

Page 11: ...ing properly The LED returns to its idle state red 2 Present the appropriate type of proximity card to the Reader The LED will flash green briefly and a short beep is emitted thus indicating that the card was read properly The Reader transmits the card s data to the Controller the Controller checks the data if the card transmission is valid the LED can change briefly to green Refer to the Controll...

Page 12: ...is warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may be requested at ROSSLAR...

Page 13: ...he Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslare be li...

Page 14: ... States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail support na rosslaresecurity com Europe Global Technical Support Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresecurity com South America Pringles 868 1640 Martinez Buenos Aires Argentina T...

Page 15: ......

Page 16: ...0706 0960127 02 www rosslaresecurity com ...