Page 1: ...MK 5800BT Bluetooth Area Imager Barcode Scanner Configuration Guide V1 1 ...

Page 2: ...ration 9 3 1 Trigger Mode 9 3 2 Presentation Mode 10 3 3 Inverse color 10 3 4 Seeep time 11 3 5 Good Read Beeper 12 3 6 Good Read Beeper Tone 12 3 7 Good Read Beeper Duration 13 3 8 Good Read Beeper Number 13 3 9 Barcode Scanning Delay 14 4 Data Formatting 15 4 1 General Configuration 15 4 2 Add Prefix 16 4 3 Add Suffix 17 4 4 Clear All Prefix and Suffix 17 5 Symbologies 18 1 3 1 4 Pairing Cradle ...

Page 3: ...2 Of 5 29 5 2 7 Matrix 2 Of 5 30 5 2 8 Industrial 2 Of 5 31 5 2 9 Code 39 32 5 2 10 Coda Bar 34 5 2 11 Code 93 35 5 2 12 GS1 128 36 5 2 13 MSI 37 5 2 14 Code 11 39 5 3 2D Symbologies 40 5 3 1 PDF 417 40 5 3 2 QR Code 41 5 3 3 Data Matrix 42 5 3 4 Maxi code 43 5 3 5 Aztec 44 5 3 6 Hanxin 45 5 4 Postal Symbologies 46 5 4 1 China Postal Code 46 5 4 2 Telepen 46 6 Appendix 47 6 1 Appendix 1 ASCII Tabl...

Page 4: ...ns for the MK 5800BT 2D Barcoder Reader Users can configure the MK 5800BT 2D Barcoder Reader by scanning the programming barcodes included in this manual 1 2 Factory Defaults Scanning the following barcode can restore the MK 5800BT to the factory defaults Restore All Factory Defaults ...

Page 5: ...en SPP 3 Scan disconnect previous pairing 4 Scan Cradle bottom BT address barcode 5 Scan Repairing 6 Scan Save BT SPP setting 7 Scan End BT SPP setting Apple device needs enable transmission other need to disable Enable iOS transmission Disable iOS transmission ...

Page 6: ...us pairing 4 Scan BT visible setting 5 Scan Save BT HID configuration 6 Scan End BT HID configuration Apple device needs enable transmission others need to disable Enable iOS transmission Disable iOS transmission Enable BT function in iPad or smart phone and then serach BT NVC_MD_CS45 to pair iPhone iPad Touch Keyboard ...

Page 7: ...6 2 Cradle Communication Interfaces 2 1 Cradle USB HID KB USB HID KB Default 2 2 Cradle USB COM Port Emulation USB COM Port Emulation ...

Page 8: ...2 3 USB Country Keyboard Types Keyboard layouts vary from country to country The default setting is 1 U S keyboard USA Germany Italy France Spain Japan Czech Denmark Belgium Finland Dutch Hungary Finlan d ...

Page 9: ...e barcode below to convert barcode data to your desired case No Case Conversion Default Convert All To Upper Case Convert All To Lower Case Example When the Convert All to Lower Case feature is enabled barcode data AbC is transmitted as abc ...

Page 10: ...9 3 General Configuration 3 1 Trigger Mode Manual Trigger Mode Normal Default Manual Trigger Mode Cellphone ...

Page 11: ...tation Mode This set the scanner to work in Continue mode Presentation Mode Normal Presentation Mode Cellphone Presentation Mode Continue Scan 3 3 Inverse color OFF Default Only Inverse ON Inverse And Normal Both ON ...

Page 12: ...11 3 4 Sleep time 5 min 10 min 30 min Always On ...

Page 13: ...12 3 5 Good Read Beeper ON Default OFF 3 6 Good Read Beeper Tone Low Middle High Default ...

Page 14: ...13 3 7 Good Read Beeper Duration Normal Default Short 3 8 Good Read Beeper Number 1 Default 2 3 ...

Page 15: ...14 3 9 Barcode Scanning Delay No Delay Default Delay 500 MS Delay 2000 MS ...

Page 16: ...15 4 Data Formatting 4 1 General Configuration Add CR Add LF Add CRLF Add TAB ...

Page 17: ...hexadecimal values of a desired prefix and then scan the Save barcode Refer to Appendix 2 ASCII Table for hexadecimal values of characters Example Set the custom Prefix to ODE 1 Check the hex values of ODE in the ASCII Table ODE 4F 44 45 2 Scan the Set Custom Prefix barcode 3 Scan the numeric barcodes 9 9 4 F 4 4 4 and 5 in Appendix 3 4 Scan the Save barcode ...

Page 18: ...ffix and then scan the Save barcode Refer to Appendix 2 ASCII Table for hexadecimal values of characters Example Set the custom Suffix to ODE 1 Check the hex values of ODE in the ASCII Table ODE 4F 44 45 2 Scan the Set Custom Suffix barcode 3 Scan the numeric barcodes 9 9 4 F 4 4 4 and 5 in Appendix 3 4 Scan the Save barcode 4 4 Clear All Prefix and Suffix Clear All Prefix And Suffix Default ...

Page 19: ...ault 5 1 2 Optimize Performance for Retail Use Case Make for optimize scan performance in most retail barcode scan use case Symbologies Enable UPC EAN Code128 QR PDF417 Only Enable Retail Barcode 5 1 3 Enable Disable All Symbologies If the Disable All Symbologies feature is enabled the engine will not be able to read any non programming barcodes except the programming barcodes Enable All Symbologi...

Page 20: ...aximum value and minimum value can be set using Programming Command Please check the programming command guide for the detail Code 128 max length command 020A03 The parameter of this command can be set from min to 90 Code 128 min length command 020A02 The parameter of this command can be set from 0 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Pro...

Page 21: ...t used to verify the accuracy of the data Transmit EAN 8 Check Digit Default Do Not Transmit EAN 8 Check Digit Add On Code An EAN 8 barcode can be augmented with a two digit or five digit add on code to form a new one In the examples below the part surrounded by blue dotted line is an EAN 8 barcode while the part circled by red dotted line is add on code ...

Page 22: ...Digit Add On Code Default Add On Code Required EAN 8 Add On Code Required EAN 8 Add On Code Not Required Default ENA JAN 8 Addenda Separator When this feature is enabled there is a space between barcode and addenda When this feature is disabled there is no space Enable ENA JAN 8 Addenda Separator Default ...

Page 23: ...PC 5 2 3 EAN 13 Enable Disable EAN 13 Enable EAN 13 Default Disable EAN 13 Transmit Check Digit Transmit EAN 13 Check Digit Default Do Not Transmit EAN 13 Check Digit Add On Code Enable 2 Digit Add On Code Disable 2 Digit Add On Code Default ...

Page 24: ...3 Add On Code Required EAN 13 Add On Code Not Required Default ENA JAN 13 Addenda Separator When this feature is enabled there is a space between barcode and addenda When this feature is disabled there is no space Enable ENA JAN 13 Addenda Separator Default Disable ENA JAN 13 Addenda Separator ...

Page 25: ...scanned ENA 13 Book land symbols are translated into their equivalent ISBN number format Enable ISBN Translate Disable ISBN Translate Default 5 2 4 UPC E Enable Disable UPC E0 E1 Enable UPC E0 Default Disable UPC E0 Enable UPC E1 Disable UPC E1 Default ...

Page 26: ...code to the 12 digits UPC A format Enable UPC E0 Expand Disable UPC E0 Expand Default UPC E0 Addenda Required When required is scanned the scanner will only read UPC E barcodes that have addenda Enable UPC E0 Required Disable UPC E0 Required Default UPC E0 Addenda Separator Enable UPC E0 Separator Default Disable UPC E0 Separator ...

Page 27: ...at the beginning of the scanned data but the unit can be programmed so it will be not transmitted Enable UPC E0 Number System Default Disable UPC E0 Number System UPC E0 Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda Default Enable 5 Digit Addenda Disable 5 Digit Addenda Default ...

Page 28: ...ult Disable UPC A UPC A Check Digit Enable UPC A Check Digit Default Disable UPC A Check Digit UPC A Addenda Required When required is scanned the scanner will only read UPC E barcodes that have addenda Enable UPC A Required Disable UPC A Required Default ...

Page 29: ... digit of UPC symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will be not transmitted Enable UPC A Number System Default Disable UPC A Number System UPC A Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda Default Enable 5 Digit Addenda Disable 5 Digit Default ...

Page 30: ...ogramming Command Please check the programming command guide for the detail Interleaved 2 of 5 max length command 020404 The parameter of this command can be set from min to 80 Interleaved 2 of 5 min length command 020403 The parameter of this command can be set from 2 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02040425 ...

Page 31: ... value and minimum value can be set using Programming command Please check the programming command guide for the detail Matrix 2 of 5 max length command 020803 The parameter of this command can be set from min to 80 Matrix 2 of 5 min length command 020802 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25...

Page 32: ...imum value and minimum value can be set using Programming command Please check the programming command guide for the detail Industrial 2 of 5 max length command 020603 The parameter of this command can be set from min to 48 Industrial 2 of 5 min length command 020602 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum...

Page 33: ...e 39 Enable Code 39 Default Disable Code 39 Transmit Start Stop Character Transmit Start Stop Character Do Not Transmit Start Stop Character Default Code 39 Check Character No Check Char Default Validate And Transmit Validate No Transmit ...

Page 34: ...ble Code 39 Full ASCII Disable Code 39 Full ASCII Default Message Length Message length can be set to the maximum value minimum value The value is valid between the maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Code 39 max length command 020308 The parameter of this command can be set from ...

Page 35: ...mand Please check the programming command guide for the detail Coda bar max length command 020206 The parameter of this command can be set from min to 60 Coda bar min length command 020205 The parameter of this command can be set from 2 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02020625 Min 02020510 Transmit Start Stop ...

Page 36: ...um and the minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail Code 93 max length command 020D03 The parameter of this command can be set from min to 80 Code 93 min length command 020D02 The parameter of this command can be set from 0 to max Example Set the Barcode Message length of the minimum value is...

Page 37: ...28 Enable Disable GS1 128 Enable GS1 128 Default Disable GS1 128 Message Length Message length can be set to the maximum value minimum value The data between the maximum and the minimum is valid The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail GS1 128 max length command 020B03 The parameter of this command can be set...

Page 38: ...n 020B0210 5 2 13 MSI Enable Disable MSI Enable MSI Disable MSI Default Message Length Message length can be set to the maximum value minimum value The data is valid between the maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail MSI max length command 020E04 The parameter of this command can be ...

Page 39: ...nsmit Validate Type10 Then Type11 Char Transmit Validate Type10 Then Type11 Char NO Transmit Validate Type10 No Transmit Validate 2 Type10 No Transmit Default Validate 2 Type10 Char Transmit Validate 2 Type10 Char No Transmit Disable MSI Check ...

Page 40: ...39 5 2 14 Code 11 Enable Disable Code 11 Disable Code 11 Default Enable Code 11 Code11 Check Digit s One Check Digit Two Check Digits Default ...

Page 41: ...een the maximum and the minimum The maximum value and minimum value can be set using Programming command Please check the programming command guide for the detail PDF417 max length command 021F06 The parameter of this command can be set from min to 2750 PDF417 min length command 021F05 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum valu...

Page 42: ...7089 QR min length command 023702 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02370325 Min 02370210 QR Code Append This function allows the scanner to append several QR barcode data together before transmitting to host When the scanner encounters a QR barcode with append cha...

Page 43: ... value can be set using Programming command Please check the programming command guide for the detail Data Matrix max length command 023603 The parameter of this command can be set from min to 3116 Data Matrix min length command 023602 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command...

Page 44: ...e and minimum value can be set using Programming command Please check the programming command guide for the detail Maxi Code max length command 023403 The parameter of this command can be set from min to 150 Maxi Code min length command 023402 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming...

Page 45: ...g Programming command Please check the programming command guide for the detail Aztec max length command 023306 The parameter of this command can be set from min to 3832 Aztec min length command 023305 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command Max 02330625 Min 02330510 Aztec A...

Page 46: ...nd minimum value can be set using Programming command Please check the programming command guide for the detail Hanxin max length command 023803 The parameter of this command can be set from min to 7833 Hanxin min length command 023802 The parameter of this command can be set from 1 to max Example Set the Barcode Message length of the minimum value is 10 the maximum value is 25 Programming command...

Page 47: ...Symbologies 5 4 1 China Postal Code Enable Disable China Postal Code Enable China Postal Code Disable China Postal Code Default 5 4 2 Telepen Enable Disable Telepen Enable China Telepen Disable China Telepen Default ...

Page 48: ...tical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOFF Device Control 3 14 20 DC4 Device Control 4 15 21 NAK Negative Acknowledgment 16 22 SYN Synchronous Idle 17 23 ETB End of Trans Block 18 24 CAN Cancel 19 25 EM End of Medium 1a 26 SUB Substitute 1b 27 ESC Esca...

Page 49: ...9 Single Quote 28 40 Right Closing Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 Less Than 3d 61 Equal Sign 3e 62 Greater Than 3f 63 Question Mark ...

Page 50: ...70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 90 Z 5b 91 Left Opening Bracket 5c 92 Back Slash 5d 93 Right Closing Bracket 5e 94 Caret Circumflex 5f 95 _ Underscore ...

Page 51: ...e Down 9E Left Arrow 9F Right Arrow A0 Up Arrow A1 Down Arrow A2 Num Lock keypad A3 1 keypad A4 2 keypad A5 3 keypad A6 4 keypad A7 5 keypad A8 6 keypad A9 7 keypad AA 8 keypad AB 9 keypad AC 0 keypad AD keypad AE keypad AF keypad B0 keypad B1 Enter keypad B2 keypad B3 Insert keypad B4 Delete keypad B5 Home keypad B6 End keypad B7 Page Up keypad B8 Page Dn keypad B9 Left Arrow keypad BA Right Arro...

Page 52: ...51 6 3 Appendix 3 Digit Barcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F ...