Optical Features
Sensor
640 x 480 pixel element, 2D CCD Array
Aiming
Visible laser diode at 650 nm
Ambient light
0 - 100000 lux
Focus distance
55 mm
Field of view
21.8° (H) x 16.2° (V)
Max Resolution
Linear codes – mm (mils)
Datamatrix – mm (mils)
0.076 (3)
0.13 (5)
Depth of field*
1D
(linear):
X-dimension – mm (mils)
DOF – cm (inches)
Code39
0.13 (5)
3.5 (1.37) to 7.0 (2.75)
2D
:
X-dimension – mm (mils)
DOF – cm (inches)
PDF417
0.13 (5)
4.0 to 7.5 (1.57 to 2.95)
0.25 (10)
4.5 to 10.0 (1.77 to 3.93)
QR
0.13 (5)
4.5 to 6.0 (1.77 to 2.36)
0.25 (10)
3.5 to 8.5 (1.37 to 3.34)
DataMatrix (4/157.4 cell)
0.13 (5)
4.5 to 6.0 (1.77 to 2.36)
DataMatrix
0.25 (10)
3.5 to 8.5 (1.37 to 3.34)
Skew ±60°
Pitch ±50°
Rotation 360°
Print Contrast (Min.)
45%
*