Error Codes
Product Reference Guide
317
Table 52
Programming Mode
- The following indications ONLY occur when the reader is in Programming Mode.
Label Program-
ming Mode
Entry
A valid programming label
has been scanned.
LED blinks continuously
Reader sounds four low fre-
quency beeps.
Label Program-
ming Mode
Rejection of
Label
A label has been rejected.
N/A
Reader sounds three times
at lowest frequency & cur-
rent volume.
Label Program-
ming Mode
Acceptance of
Partial Label
In cases where multiple
labels must be scanned to
program one feature, this
indication acknowledges
each portion as it is success-
fully scanned.
N/A
Reader sounds one short
beep at highest frequency &
current volume.
Label Program-
ming Mode
Acceptance of
Programming
Configuration option(s) have
been successfully pro-
grammed via labels and the
reader has exited Program-
ming Mode.
N/A
Reader sounds one high fre-
quency beep and 4 low fre-
quency beeps followed by
reset beeps.
Label Program-
ming Mode
Cancel Item
Entry
Cancel label has been
scanned.
N/A
Reader sounds two times at
low frequency and current
volume.
. Programming Mode Indications
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has
not passed its automatic Selftest and has entered FRU (Field Replaceable
Unit) isolation mode. If the reader is reset, the sequence will be repeated.
The following table describes the LED flashes/beep codes associated with an
error found.
NUMBER OF
LED FLASHES/
BEEPS
ERROR
All Models:
GD44XX, GBT4400, GM44XX
CORRECTIVE ACTION
1
Configuration
Contact Helpdesk for
assistance
2
Interface PCB
6
Digital PCB
12
Imager
15
Accelerometer
Summary of Contents for Gryphon I GD4400
Page 40: ...Setup 38 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 44: ...Enter Exit Programming Mode 42 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 58: ...Enter Exit Programming Mode 56 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 68: ...Enter Exit Programming Mode 66 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 78: ...Enter Exit Programming Mode 76 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 102: ...Enter Exit Programming Mode 100 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 248: ...246 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 308: ...References 306 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 338: ...Keypad 336 Gryphon I GD44XX GBT4400 GM440X A B C D E F...
Page 348: ...Scancode Tables 346 Gryphon I GD44XX GBT4400 GM440X NOTES...