Enter/Exit Programming Mode1D Code Selection
156
Gryphon™ I GD44XX/GBT4400/GM440X
CODE 128
The following options apply to the Code 128 symbology.
Code 128 Enable/Disable
When disabled, the reader will not read Code 128 bar codes.
$CC8EN00(CR)
Code 128 = Disable
$CC8EN01(CR)
Code 128 = Enable
DEFAULT
Expand Code 128 to Code 39
This feature enables/disables expansion of Code 128 labels to Code 39
labels.
DEFAULT
$CC8C300(CR)
Code 128 to Code 39 = Don’t Expand
$CC8C301(CR)
Code 128 to Code 39 = Expand
Summary of Contents for Gryphon I GD4400
Page 40: ...Setup 38 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 44: ...Enter Exit Programming Mode 42 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 58: ...Enter Exit Programming Mode 56 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 68: ...Enter Exit Programming Mode 66 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 78: ...Enter Exit Programming Mode 76 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 102: ...Enter Exit Programming Mode 100 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 248: ...246 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 308: ...References 306 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 338: ...Keypad 336 Gryphon I GD44XX GBT4400 GM440X A B C D E F...
Page 348: ...Scancode Tables 346 Gryphon I GD44XX GBT4400 GM440X NOTES...