References
274
Gryphon™ I GD44XX/GBT4400/GM440X
ACK NAK Options
This enables/disables the ability of the reader to support the RS-232 ACK/
NAK protocol. When configured, the reader and/or host sends an “ACK”
when it receives data properly, and sends “NAK” when the data is in error.
Options are:
• Disable
• Enable for label transmission — The reader expects an ACK/NAK
response from the host when a label is sent.
• Enable for host-command acknowledge — The reader will respond with
ACK/NAK when the host sends a command.
• Enable for label transmission and host-command acknowledge
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK
character. ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option
has been set as 7
Data Bits.
1. Determine the desired character or value.
2. Use the
on the inside back cover of this manual to find the
hex equivalent for the desired character/value.
3. Go to
and scan ENTER/EXIT PROGRAMMING MODE to enter
Programming Mode.
4. Scan the bar code: SELECT ACK CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
, that represent the desired character/value in step
1 above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
See
for some examples of how to set this feature.
Table 26. ACK Character Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Character/Value
ACK
$
@
>
2
Hex equivalent from
0x06
0x24
0x40
0x3E
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT ACK CHARACTER SETTING
5
Scan Two Characters from
‘0’ and ‘6’
‘2’ and ‘4’
‘4’ and ‘0’
‘3’ AND ‘E’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for Gryphon I GD4400
Page 40: ...Setup 38 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 44: ...Enter Exit Programming Mode 42 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 58: ...Enter Exit Programming Mode 56 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 68: ...Enter Exit Programming Mode 66 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 78: ...Enter Exit Programming Mode 76 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 102: ...Enter Exit Programming Mode 100 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 248: ...246 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 308: ...References 306 Gryphon I GD44XX GBT4400 GM440X NOTES...
Page 338: ...Keypad 336 Gryphon I GD44XX GBT4400 GM440X A B C D E F...
Page 348: ...Scancode Tables 346 Gryphon I GD44XX GBT4400 GM440X NOTES...