TROUBLESHOOTING
318
AV7000 LINEAR CAMERA
Warning: Forced Fixed Gain in
PE Only Mode
Warning
Camera is being forced into
Fixed Gain because the
Photo Sensor is set to
Photo-eye only mode.
Photo Sensor is set to PE Only
and gain is set to Profile. The
RTP will force gain to fixed in
this case.
Set gain to fixed and set fixed gain
and fixed exposure.
Warning: Illumination Fan1
Failed
Warning
The external fan mounted to
the illumination has stopped
functioning.
Fans are disconnected. Fan
hardware failure.
Verify the external fans are con-
nected properly. Replace fan
assembly.
Warning: Illumination Fan2
Failed
Warning
The external fan mounted to
the illumination has stopped
functioning.
Fans are disconnected. Fan
hardware failure.
Verify the external fans are con-
nected properly. Replace fan
assembly.
Warning: Internal fan failure
Warning
The internal fan has stopped
functioning.
Internal fan hardware failure.
Cycle the unit’s power. If the error
persists, replace the camera and/or
contact Datalogic Support.
Warning: Invalid End of IV
Detected
Warning
The RTP tried to end a new
package before the new
package started.
Parameter update was per-
formed with packages run-
ning. Multiple focusing
devices connected.
Contact Datalogic Support.
Warning: Invalid Start of IV
Detected
Warning
The RTP tried to start a new
package before the previous
package ended.
Parameter update was per-
formed with packages run-
ning. Multiple focusing
devices connected.
Contact Datalogic Support.
Warning: Linerate exceeds
Maximum Linerate
Warning
The required line rate is
exceeding the maximum
expected line rate based on
the belt speed.
The belt speed parameter is
set below the actual belt
speed. The LPI is set too high.
Verify the belt speed is set just
above the actual maximum belt
speed. Verify the LPI is set correctly
to the application specification.
Info: Failed to Send Focus
Command
Info
The camera is unable to send
messages to the focus
servo.
Internal communication fail-
ure.
Cycle the unit’s power. If the error
persists, replace the camera and/or
contact Datalogic Support.
Info: Focus Command Above
Max Range
Info
RTP attempted to focus
beyond the far working dis-
tance of the camera.
Far working distance is not
set to the left/right edge of
the DM3610 or RangeFinder.
Make sure the far working distance
of the camera is set to the left/
right edge of the DM3610 or
RangeFinder.
Info: Focus Command Below
Min Range
Info
RTP attempted to focus
beyond the near working
distance of the camera.
The camera is mounted too
close.
Physically move the camera farther
away.
Info: Invalid Height from Posi-
tion Sensor
Info
Height received from the
position sensor is out of
range.
Package presented was too
tall causing the camera to
attempt to focus beyond its
near working distance.
Physically move the camera farther
away from the conveyor surface.
Info: Invalid Left Offset from
Position Sensor
Info
Left offset received from the
position sensor is out of
range.
Far working distance of right
side cameras is not set to the
left edge of the DM3610/
Rangefinder or the left offset
of the DM3610/ Rangefinder
caused a left side camera to
attempt to focus beyond its
near working distance.
Make sure the cameras are
mounted properly and the far
working distance of each camera
matches the DM3610/Range-
Finder left/right edges.
Info: Invalid Right Offset from
Position Sensor
Info
Right offset received from
the position sensor is out of
range.
Far working distance of left
side cameras is not set to the
right edge of the DM3610/
Rangefinder or the right off-
set of the DM3610/Range-
finder caused a right side
camera to attempt to focus
beyond its near working dis-
tance.
Make sure the cameras are
mounted properly and the far
working distance of each camera
matches the DM3610/Range-
Finder left/right edges.
Info: Issue Writing to Network Info
The RTP could not write a
message to the network.
A network issue exists
between the RTP and com-
puting module.
Cycle the unit’s power. If the error
persists, replace the camera and/or
contact Datalogic Support.
Info: Maximum Digital Gain
being used
Info
The digital gain value being
used is the maximum value
allowed. This could result in
noisy and/or dark images.
Conveyor Speed and/or LPI
settings are too high. Physical
belt speed is too high for the
LPI setting required.
Reduce LPI. Make sure the Con-
veyor speed parameter is set prop-
erly. Contact Datalogic Support if all
settings are correct.
Info: Reading Calibration
tables...
Info
RTP is in the process of
reading calibration tables.
This only happens during
boot up.
Not an issue.
Wait until the calibration tables are
loaded.
e-Genius Description
Type
Explanation
Possible Cause
Solution
Summary of Contents for AV7000
Page 1: ...AV7000 PRODUCT REFERENCE GUIDE Linear CAMERA...
Page 48: ...MECHANICAL INSTALLATION 34 AV7000 LINEAR CAMERA...
Page 49: ...INSTALLATION SEQUENCE PRODUCT REFERENCE GUIDE 35...
Page 55: ...INSTALLING THE DEFLECTION MIRROR PRODUCT REFERENCE GUIDE 41...
Page 57: ...INSTALLING THE DEFLECTION MIRROR PRODUCT REFERENCE GUIDE 43...
Page 60: ...MECHANICAL INSTALLATION 46 AV7000 LINEAR CAMERA...
Page 66: ...ELECTRICAL INSTALLATION 52 AV7000 LINEAR CAMERA Controller Client Array with DM3610...
Page 69: ...TYPICAL CONNECTION BLOCK DIAGRAMS PRODUCT REFERENCE GUIDE 55 AV7000 in Hybrid Configuration...
Page 80: ...ELECTRICAL INSTALLATION 66 AV7000 LINEAR CAMERA Photoelectric Sensor to CBX510 PNP...
Page 96: ...ELECTRICAL INSTALLATION 82 AV7000 LINEAR CAMERA Unpowered Outputs...
Page 97: ...CBX100 CBX510 CBX800 INITIAL CONFIGURATION PRODUCT REFERENCE GUIDE 83 Powered Outputs...
Page 116: ...E GENIUS 102 AV7000 LINEAR CAMERA...
Page 134: ...E GENIUS 120 AV7000 LINEAR CAMERA...
Page 175: ...PRODUCT REFERENCE GUIDE 161 4 Again run the small package through the system...
Page 239: ...PRODUCT REFERENCE GUIDE 225 12 Click Update to save your changes...
Page 278: ...FOCUSING SETUP AND CALIBRATION 264 AV7000 LINEAR CAMERA...
Page 309: ...READING LINEAR BARCODES PRODUCT REFERENCE GUIDE 295 READING LINEAR BARCODES...
Page 310: ...AV7000 FEATURES 296 AV7000 LINEAR CAMERA...
Page 311: ...PRODUCT REFERENCE GUIDE 297...
Page 312: ...AV7000 FEATURES 298 AV7000 LINEAR CAMERA...
Page 313: ...PRODUCT REFERENCE GUIDE 299 READING 2D BARCODES...
Page 314: ...AV7000 FEATURES 300 AV7000 LINEAR CAMERA...
Page 315: ...PRODUCT REFERENCE GUIDE 301...
Page 316: ...AV7000 FEATURES 302 AV7000 LINEAR CAMERA...
Page 336: ...TROUBLESHOOTING 322 AV7000 LINEAR CAMERA 4 Click Stop Acquiring to freeze the scope...
Page 350: ...TECHNICAL FEATURES 336 AV7000 LINEAR CAMERA...
Page 351: ......