AREX
TM
30W – 50W
32
2
2.5 INPUT/OUTPUT SIGNAL SPECIFICATIONS
DIGITAL INPUT:
Type
Optocoupler
V
max
24V DC
I
max
5mA @ 24V DC
Pulse Width
≥ 1ms (debounce)
MIN
TYP
MAX
INPUT Logic LOW
0.0 V DC
0.0 V DC
2.0 V DC
INPUT Logic HIGH
5.0 V DC
12.0 V DC
24.0 V DC
DIGITAL OUTPUT:
Type
Low side driver
V
max
24V DC
I
max
250mA
Vsaturation
<0.5V DC
Leakage current
< 5µA
OUTPUT State ON
V ≤ 0.5 V DC; I ≤ 250mA
OUTPUT State OFF
V ≤ 24 V DC; I ≤ 5µA