2.4.2.4 MARKING PROCESS SIGNALS TIMING
The following diagram illustrates the possible timings and settings of these signals:
Figure 18: Timing signals
The time intervals in the diagram can all be programmed with a resolution of 1 ms
(*)
.
T
1
Start Time
For setting the minimum acceptable time for the
START_MARKING
signal
T
2
Start Delay
For delaying the start of marking process
T
3
Busy Advance
BUSY
signal corresponding to marking progress
T
4
Stop Time
The minimum time for stop signal to stop the marking process
T
5
Busy Delay
For delaying the Laser
END
signal with respect to laser emission
T
6
End Time
For setting the Laser
END
activation time
(*) Refer to Lighter user’s manual “Setting I/O parameters” to set the signal’s properties.