AREX
TM
30W – 50W
22
2
2.4 CONNECTORS SPECIFICATIONS
2.4.1 INTERLOCK CONNECTOR
Interlock
disables
the Class 4 laser source inside the laser system. Interlock internal circuit is designed to
comply with the single fault condition.
PANEL CONNECTOR
Type SWITCHCRAFT TB Series male Tini Q-G (Mini XLR) panel mount connector, 4 positions.
Figure 12: Male panel plug cod. TB4M (front view).
NOTE:
See appendix D about the compliance to EN ISO 13849-1:2008.
PIN SIGNAL
TYPE
DESCRIPTION
FUNCTIONAL DIAGRAM
1
VCC_INT_A
OUTPUT
24V DC reference for
INTERLOCK
IN signal A
2
INTERLOCK_A
INPUT
INTERLOCK
IN signal A
3
GND
GND
Ground reference for
INTERLOCK
IN signal B
4
INTERLOCK_B
INPUT
INTERLOCK
IN signal B
PIN 1- PIN 2
PIN 3- PIN 4
MARKING FUNCTIONALITY CONDITION
CONTACT OPEN
CONTACT OPEN
NOT POSSIBLE
SAFE
CONTACT CLOSED
CONTACT OPEN
NOT POSSIBLE
DANGEROUS
CONTACT OPEN
CONTACT CLOSED
NOT POSSIBLE
DANGEROUS
CONTACT CLOSED
CONTACT CLOSED
POSSIBLE
DANGEROUS
WARNING!
In order to
NOT DAMAGE
the interlock circuitry, we recommended using “dry circuit” (zero voltage)
switches or relay circuitry.