i50 Manual (5.51)
Page 29
© 2018 Datalink Systems, Inc.
www.datalinksystemsinc.com
Alarm
Alarm State:
Value used internally to track alarm status.
Alarm ID:
Counter used to identify alarms.
Alarm Pass:
Not currently used.
Report Intervals
City Threshold:
Unit uses City reporting settings when speed drops below this
value. If set to zero, city settings are used whenever the i50 is
stationary. See note on highway threshold setting.
Highway Threshold:
Unit switches to Highway reporting settings when speed
reaches this value. If set to zero, highway settings are used
whenever the i50 is moving. See section 6.3 for information on
how the i50 detects motion. Note: when unit speed is between
the city and highway thresholds, the current city/highway mode
is maintained. If both thresholds are active, the city threshold
will be selected. When the city/highway mode changes, the
shortest time and distance settings will be selected until the
next report is triggered.
City Time Reports:
Used to enable periodic position reports in City mode. Options
are provided to disable these reports when IGN is off or device
is stationary.
City Max Time:
Interval for City periodic reports.
Highway Time Reports:
Enable periodic position reports in Highway mode.
Highway Max Time:
Interval for Highway periodic reports.
City Distance Reports:
Enable position reports based on distance travelled in City
mode.
City Distance:
Distance between reports in City mode.
City Min Time:
Minimum time between reports in City mode.
Highway Distance Reports:
Enable position reports based on distance travelled in Highway
mode.
Highway Distance:
Distance between reports in Highway mode.
Highway Min Time:
Minimum time between reports in Highway mode.
Dual-Mode Min Time/Dist:
Minimum time/distance between sending reports when
operating on satellite network and unit is configured to use both
satellite and terrestrial modems. Note: reports will still be
generated and stored based on the City/Highway settings, but
only sent if the dual-mode settings have been reached. Set to
zero to disable.