![Datafox Evo 4.6 FleKey Manual Download Page 89](http://html.mh-extra.com/html/datafox/evo-4-6-flekey/evo-4-6-flekey_manual_511640089.webp)
Manual Datafox Evo 4.6 FleKey
Page 82
Date: 14.09.2021 V 04.03.17.XX
Table
Location
(defines which card groups get access to which room at which time)
Identifier
Data type
Length
Description
ID
Number
(int)
4
ID of the room. All other tables refer to this data line via this number, if neces-
sary.
RefGroup
Number
(int)
4
Reference to the identification table. Labels the access authorized group. All
cards of this group have access to this room.
RefTime
Number
(int)
4
The time model in which authorized persons get access. (0 = not used)
RefTimeNoPin
Number
(int)
4
The time model for which entering an additional PIN is not necessary (at peak
times etc.).
Table
Time
(grouping of single time zones (weekday from to) as a time model number)
Name
Data type
Length
Description
ID
Number
(int)
4
ID of the time model. All other tables refer to this data line via this number, if
necessary.
Weekdays
Number
(int)
7
Indicates the weekdays on which the following period of time should be ap-
plied (form: 7 digits at most 1-7 e.g. 134567 = Monday, Wednesday till Sun-
day)
TimeStart
Text
(Time)
5
The start point for the period of time. (form: 24h HH:MM)
TimeEnd
Text
(Time)
5
The end point for the period of time.
Table
Holiday
(setting blocking days like holidays or company holidays)
Name
Data type
Length
Description
Day
Text
(Date)
10
Date of the blocking day. (form: YYYY-MM-DD)
RefGroup
Number
(int)
4
Indicates the authorization group to which the blocking day is applied. Zero
defines a global validity for all groups.
RefTime
Text
(Time)
4
Indicates the assigned time model. (0 = not used) During this time access is
granted. Thus, also "‘half holidays"’ like New Year’s Eve can be realized.
Table
Event
(assigning an action to a signal at the digital input)
Name
Data type
Length
Description
RefReader
Number
(int)
4
Module (door module or master) where the digital input is.
PortIn
Number
(int)
1
Number of the digital input on the module.
RefAction
Number
(int)
4
Reference to the action that should be carried out (e.g. switch relay).
RefTime
Number
(int)
4
The time model which indicates when the digital input is checked. (0 = not
used).