General Specifications
System
•
2U enclosure height (rack configurations)
•
Up to 24 2.5" SAS or SATA disk drives (including SSD’s) per enclosure (6 Gb/sec or
3 Gb/sec)
Redundant Components
•
Two APC units
•
Up to 24 drives per enclosure
Field Replaceable Units
•
Disk drives and drive carrier blanks
•
APC units
•
I/O modules
•
I/O module slot blanks
Enclosure Physical Dimensions
•
Height: 3.5" (89 mm)
•
Width: 17.6" (447 mm)
•
Depth: 19.3" (49 mm)
•
Weight: up to 53 lbs (27 kg) maximum (with all drives installed)
Advanced Power and Cooling (APC) Units
•
Input Voltage: 100–240 VAC
•
Current Rating: 8.40 A (max)
•
Input Frequency: 50/60 Hz
•
Outputs:
- +5 V @ 28 A
- +12 V @ 43 A
•
Maximum Average Output Power: 550 Watts
•
Cooling: Variable speed blowers, two per APC for a total of four blowers per enclosure
NOTE :
APC units are hot-swappable.