Introduction
96-00290-001 Rev. A1
DataDirect Networks StorageScaler 2460 User Guide | 5
NOTE :
A disk drive must not be removed from its drive carrier. A disk drive removed
from its carrier is not covered by the hardware warranty.
NOTE :
All SATA disk drives installed in a dual-controller system require the use of a
2:1 SATA MUX assembly. Please contact your DataDirect Networks sales
representative to obtain the MUX cards.
Each drive carrier has three LEDs, which indicate status as described in Section
3.3
,
Monitoring the Disk Drives
.
To maintain proper airflow and cooling inside the enclosure, drive slots
(Figure 6)
cannot be
left empty. Blank drive carriers are available to fill empty drive slots.
Figure 6. Drive Slot Numbering
1.7
Advanced Power and Cooling (APC) Units
Figure 7. APC Unit
LED
Power Switch
Power
Cord
Connector
Each SS2460 enclosure is equipped with two APC units
(Figure 7)
located on the back of the
enclosure.
The cooling fans in each APC unit run on separate circuits from the power supply.
Therefore, if one APC unit fails, its fans continue to run on power supplied by the other APC
unit.
Each APC unit has four LEDs, which indicate status as described in Section
3.4
,
Monitoring
the APC Units
.
APC units are hot-swappable. See Section
4.4
,
Replacing an APC Unit
for more information.