Monitoring Your SS2460
96-00290-001 Rev. A1
DataDirect Networks StorageScaler 2460 User Guide | 20
3.2
Monitoring the Controllers
Each controller has 11 status LEDs
(Figure 26)
. The LEDs are defined in
Table 2
.
Figure 26. Controller Status LEDs
OK/Power
Ethernet LEDs
SAS Link Fault
SAS Link
Established
Locate
I/O Fault
When a fault condition occurs on a controller, the enclosure LEDs indicate an enclosure
fault. Because the controllers are on the back of the enclosure where they may be hard to
see, always check controller status whenever the enclosure LEDs indicate a fault.
When the controller Fault LED illuminates, replace the controller (see
Section
4.2
).
Table 2. I/O Controller LED Description
OK / Power
Green
I/O Module Fault
Amber
Locate Beacon
Blue
SAS Link
Established
Green
SAS Link Fault
Amber
Ethernet Link
Green
Ethernet Activity
Amber
LED
Color
Description
ON - the I/O module is properly booted and is functioning properly
OFF - the I/O module has detected an internal fault
ON - an I/O module fault has been detected
OFF - no detectable I/O module faults
Flashes - receiving Locate command
OFF - NOT receiving Locate command
ON - a valid SAS link is established on at least one of the four SAS links
of the 4-wide SAS port
OFF - no valid SAS link is established on any of the four SAS links of the
4-wide SAS port
ON - a detectable fault is present on at least one of the four SAS links of
the 4-wide SAS port
OFF - no detectable fault is present on any of the four SAS links of the
4-wide SAS ports
ON - Ethernet link is up
OFF - Ethernet link is down
Flashes - Ethernet link is active; the frequency that it will blink is 10 Hz