21
© 2010 Datacom Systems Inc
Hardware Installation
VERSA
™
stream
5 Hardware Installation
This section specifically describes the FVS-1080 hardware installation at the network site of your choice. The
FVS-1044 is similar in functionality and the same basic installation procedure may be used as a guide during
FVS-1004 installation.
5.1 Power
This section describes the installation site power connection of the FVS-1080 at the network site.
Two AC input power sockets are provided on the rear panel. The front panel
POWER 1
and
2
LEDs are
illuminated
green
, respectively when AC power is available at both the two rear AC power sockets.
Either
POWER 1
or
2
LED not illuminated when powered, indicates a defective power source and immediate
investigation as to the cause is required to insure redundant power integrity.
Step 1.
Using the supplied AC Line Cords, plug the FVS-1080 series product into different circuit external
power sources. Although only one external power source is required to power the unit, use of a second
independent external power source is strongly recommended to assure uninterrupted monitoring. Furthermore,
connecting to a second different external power source circuit than the first AC power source eliminates power
as a single point of failure.
5.2 Management Connection
This section shows the
MANAGEMENT
port 100 Mbs fixed full-duplex connection of the typical FVS-1080
hardware installation.
Step 1.
Connect a network cable to the
MANAGEMENT
port RJ45 socket. The
MANAGEMENT
port RJ45 left
LED illuminates
green
when link has been established with the network. The
MANAGEMENT
port right LED
illuminates
green
when passing data.
Step 2.
Refer to the FLOW
control
help file for detail operation of the FVS-1080 filtered product.
The
MANAGEMENT PORT
is an RJ45 socket used for 100 Mbs fixed full-duplex connection with a straight-
through LAN cable via your management LAN to a Remote Management Console which is a standard PC
running FLOW
control
.
Link indicates connection. The LED Display Code table deciphers the RJ45 jacks with integrated LEDs that
display line status of the
MANAGEMENT PORT
.