17
© 2010 Datacom Systems Inc
Initial Configuration
VERSA
™
stream
4 Initial Configuration
IMPORTANT:
Review the following section prior to initial configuration of the hardware.
IMPORTANT:
Detailed Command Line Interface (CLI) syntax information is found in the '
Appendix
1 - Command Line Interface (CLI)
' section.
Initial configuration is performed directly with a terminal emulation application on a management PC connected
to the FVS through the
SERIAL
USB-style type A port. After initial configuration, the FVS can be remotely
operated though the
MANAGEMENT
RJ45 port. Only one configuration session can be open at a time.
4.1 SERIAL Port Configuration
Once the FVS
SERIAL
port hardware connection is made, open the terminal emulator application on the
management PC and create a connection with the settings that fit your needs:
FVS-1044
FVS-1080
2400 bits per second
9600 bits per second
8 data bits
8 data bits
Parity none
Parity none
1 stop bit
1 stop bit
Flow control none
Flow control none
4.2 IP Address
All FVS filtered products are assigned an IP address (192.168.1.1) by default. You must change the IP
address to match your network.
NOTE:
If your FVS already has an IP address for your network, you may proceed to the '
Small Form-Factor
Plug Module
' section.
Step 1.
First, connect your terminal emulator application PC and FVS using the provided Datacom Systems
DRL434-6-R cable. Connect the DB9 Female pin end to the serial port on your PC and connect the USB-
style Type A end to the
SERIAL
port on the unit.
NOTE:
For PCs without 9-pin serial ports, check with you product representative for available sources
of a USB to RS-232 Plug-in Adapter.
Step 2.
Open the terminal emulator application on your PC.
Step 3.
Create a serial link by selecting the
COM
port assigned to the serial port on your PC.
Step 4.
Next, configure the
COM Properties
. The initial correct setting to communicate with the FVS series
product (9600, 8, None, 1, None) are shown below. Once all settings are configured correctly, you can
connect to your Filtered
VERSA
stream
™
product.
Step 5.
Next, plug the FVS into the external power source using the supplied AC line cord. Note that either
POWER 1
or
2
LED is illuminate
green
indicating power is available at the rear AC power socket to which the
AC Line Cord is connected. The other
POWER
LED is not illuminated, indicating a lack of power to the
unconnected AC power socket.
73