PCIe-FRM11 User’s Manual (Rev 1.4)
-
27
- http://www.daqsystem.com
To run the sample application program, you need to use API, it is a form of client DLL. To
compile the sample source to make its executable file, you have to use Import Library files and
header files. You can find them in the CDROM. To run the .exe file, the API DLL file
(PCI_FRM11.DLL)
must be in the same directory with the .exe file or Windows system folder.
Another method is to add the directory of API DLL file to PATH environmental variable.
[Figure 5-1]
Execution sequence for sample program as shown below
“Device Init” click
“Start” click
“Get Info.”
“Video Data Bits” after select of mode “8Bit, 16Bit YUV, 24Bit”
Select" Set Detected "and then select the screen size selected in" Set Resolution ".
“Frame View” show only one screen
“Auto” check show continuous screen
5.1.1 Functions related to Image Frame
(1) “
Set Resolution”
“Set Detected” Selection
It is selected according to the input resolution. The user can set the resolution is 640 x 480,
800 x 600, 1024 x 768, 1280 x 720, 1280x1024, 1600 x 1200, 1920 x 1080, 1920 x 1200,
2048 x1536, 2560 x 2048.
(2)
Board # selection
Select a board number which set up the system. (#0 ~ #3)
(3)
„Device Init‟ button
Press this button to initialize the function of receiving image frame data. It is performed only
once after power is applied to the board.
(4)
„Start‟ button
Press this button to begin to save image data.
(5)
„Get Info‟ button
Displays the current error message and the resolution of the actual pixel frequency and image.
Error message 0: OK,
Bit 0 : PCLK error, Bit 1 : HSYNC error, Bit 2 : VSYNC error
(6)
“Get Size” button
Displays the resolution of the image currently set to Set Detected.
(7)
F/R
It shows the Frame Rate.