![Dantel 46502 Installation & Operation Manual Download Page 36](http://html1.mh-extra.com/html/dantel/46502/46502_installation-and-operation-manual_3460503036.webp)
P
AGE
36
46502-0999 <90-00021>
Here are descriptions of each parameter:
Com Port - Specifies which communications port to use. Accept-
able entries are 1 - 4. This field defaults to 1.
NOTE:
The terminal emulator can use the same communica-
tions port that the T/Shell software uses for its external
communications. This is possible because, when you exit the
terminal emulator, the communications port is reset to its
original configuration.
Baud - Specifies the baud rate for the communications port.
Acceptable baud rates are 110, 150, 300, 600, 1200, 2400, 4800,
9600, 19 (19,200) and 38 (38,400). This field defaults to 1200.
Word - Specifies the number of word bits for the communica-
tions port. Acceptable values are 7 and 8. This field defaults to 8.
Stop - Specifies the number of stop bits for the communications
port. Acceptable values are 1 and 2. This field defaults to 1.
Parity - Specifies the parity for the communications port.
Acceptable values are E)ven, O)dd, N)one. This field defaults to
None.
Echo - Specifies how the terminal emulator communicates.
Acceptable values are Y)es, echo (results in half duplex opera-
tion) and N)o, don’t echo (results in full duplex operation). This
field defaults to N.
Append LF - Tells the computer whether to add a linefeed
when it receives an Enter (CR or carriage return) command.
Acceptable values are Y)es, append a linefeed character after
Enter and N)o, don’t append a linefeed after Enter. This field
defaults to N.
Term Emul - Selects the specific type of terminal the computer
emulates. Partial emulation of ADDS Viewpoint functions is
available by selecting A. The available ADDS Viewpoint func-
tions are clear screen, clear to the end of line, and cursor posi-
tioning. Select N (none) for no terminal emulation. This field
defaults to None.
Prot Base - Specifies the number base that the Debug Mode
uses to display data. Acceptable values are D (decimal) and H
(hexadecimal). This field defaults to D.
Capture File - Displays the name and status of a capture file if
one is open.
NOTE:
You cannot change the Capture File parameter while editing
the terminal configuration.
TERMINAL EMULATOR