STEP 1
(
Selecting a Site
)
Before installing your new lift, check the following.
1.
LIFT LOCATION
: Always use architects plans when
available. Check layout dimension against floor plan
requirements making sure that adequate space if avail-
able.
2.
OVERHEAD OBSTRUCTIONS
: The area where the
lift will be located should be free of overhead obstruc-
tions such as heaters, building supports, electrical lines
etc.
3.
DEFECTIVE FLOOR
: Visually inspect the site where
the lift is to be installed and check for cracked or defec-
tive concrete.
4.
OPERATING TEMPERATURE.
Operate lift only
between temperatures of 41° -104° F.
5. Lift is designed for
INDOOR INSTALLATION ONLY.
STEP 2
(
Floor Requirements
)
This lift must be installed on a solid level concrete
floor with no more than 3-degrees of slope. Failure
to do so could cause personal injury or death.
t
DO NOT
install or use this lift on any asphalt surface
or any surface other than concrete.
t
DO NOT
install or use this lift on expansion seams
or on cracked or defective concrete.
t
DO NOT
install or use this lift on a second / elevated
floor without first consulting building architect.
LIFT MODEL CONCRETE REQUIREMENTS
12,000 Lb Models: 6.5” Min. Thickness 3,000 PSI
15,000 Lb Models: 8” Min. Thickness 3,000 PSI
All models MUST be installed on 3,000 PSI concrete only,
conforming to the minimum requirements shown above.
New concrete must be adequately cured for at least
28 days minimum.
IMPORTANT NOTICE
These instructions must be followed to ensure proper installation and operation of your lift. Failure to comply
with these instructions can result in serious bodily harm and void product warranty. Manufacturer will assume
no liability for loss or damage of any kind, expressed or implied resulting from improper installation or use of
this product.
t
Rotary Hammer Drill or Similar
t
3/4” Masonry Bit
t
Hammer
t
4 Foot Level
t
Open-End Wrench Set: SAE/Metric
t
Socket And Ratchet Set: SAE/Metric
t
Hex-Key / Allen Wrench Set
t
Large Crescent Wrench
t
Large Pipe Wrench
t
Crow Bar
t
Chalk Line
t
Medium Flat Screwdriver
t
Tape Measure: 25 Foot Minimum
t
Needle Nose Pliers
TOOLS REQUIRED
IMPORTANT NOTE:
Dannmar lifts are supplied with installation
instructions and concrete fasteners meeting the
criteria as prescribed by the American National
Standard "Automotive Lifts - Safety Requirements for
Construction, Testing, and Validation" ANSI/ALI ALCTV.
Lift buyers should contact qualified persons
regarding any special regional structural and/or
seismic anchoring requirements specified by any
other agencies and/or codes such as the Uniform
Building Code (UBC) and/or International Building
Code (IBC).
CONCRETE
SPECIFICATIONS
Summary of Contents for D2-12C
Page 13: ...13 HOSE ROUTING Side of Column...
Page 38: ...38...
Page 39: ...39...
Page 40: ...40...
Page 41: ...41...
Page 42: ...42 42...
Page 43: ...43 43...
Page 44: ...44...
Page 45: ...45...
Page 46: ...46...
Page 47: ...47...
Page 48: ...48...