18
ENSURE THAT BOTH THE POWER SIDE & OFF
SIDE SAFETIES ENGAGE PROPERLY PRIOR TO
LIFT OPERATION.
Fig 9.3
Slip looped end
over bottom pin
Insert non-looped
end of safety
cable through
hole in Column
Fig 9.4
Route safety cable
under Off Side
safety sheave and up
towards Overhead
Assembly
NOTE: Column cut away for clarity
Fig 9.5
Safety
Cable
NOTE: Top plate cut away for clarity
Route safety
cable over the top
pin of the Power
Side Safety
Weldment
Tighten jam
nuts ensuring
safety cable is
centered in hole
Route safety
cable the
hole in the
threaded pin
NOTE:
M
AKE SURE TO KEEP THE SAFETY CABLE
CENTERED WHEN TIGHTENING JAM NUTS
ON SAFETY.
Fig 9.6