Picture F14.1: Position of the weights in the various Program Types along the section of the rim
Angular position of the balancing weights in the several Program Type is shown in table T14.2.
Table T14.2:
Angular position of the balancing weights in the various Program Types
Machine
data
acquisition
system
Program Type
STD,
ALU1,2,3,4,5
ALS1
ALS2
Internal
plane
External
plane
Static
plane
Internal
plane
External
plane
Static
plane
Internal
plane
External
plane
Static
plane
Semi-automatic
H12
H12
H12
H12
Sensor-
rim
contact
point
(1)
H6
Sensor-
rim
contact
point
(1)
Sensor-
rim
contact
point
(1)
H6
Automatic
H12
H12
H12
H12
Sensor-
rim
contact
point
(1)
H6
Sensor-
rim
contact
point
(1)
Sensor-
rim
contact
point
(1)
H6
Laser
H12
H12
H12
H12
H6
Sticker
H6
H6
Sticker
H6
Sticker
H6
Note
(1)
: if the data acquisition system is disabled, the angular position of the weight will be in the 6 o’clock position.
In table T15.2 the symbol “H12” indicates that the angular position of the weight is at 12 o’clock while the symbol “H6” indicates
that the angular position of the weight is at 6 o’clock.
The machine data acquisition systems are defined as follows:
Semi-automatic when the Distance and Diameter data are automatically acquired with the Distance/Diameter sensor
while the data on the width must be manually entered;
Automatic when all data of the rim is automatically acquired with the two sensors.