14
240
Calibration is finished: the machine automatically exits the calibration program
and returns to the NORMAL mode, ready to perform the balancing.
At any time it is possible to exit the calibration procedure by pressing [5] key.
13.2 Machine calibration for the MOTO wheel type
The calibration for MOTO wheel type (motorcycle wheels) is completely separated from CAR/SUV wheel type because in the
calibration for MOTO a specific adaptor for motorcycle wheels is used
If the calibration for MOTO wheel type has not been done and the user try to spin the wheel for balancing in the MOTO wheel type
mode, the machine will not run and will display an error code
ERR 031
.
To perform the machine calibration with adaptor for motorcycle wheels, proceed as follows:
Op.
Description
10
Press [2] or [4] from the keyboard
and select
the icon relative to the programme to be used.
20
Activate the MOTO calibration programme by selecting
which will
turn green.
30
Confirm activation of the MOTO calibration programme by pressing [6] on the
keyboard.
40
Mount the motorcycle adaptor on the shaft as shown here.
50
Lower the wheel guard: the machine will run a launch.
CA
CAL
CAL
CAL
CAL
CAL
CAL