13. MACHINE CALIBRATION
To function properly, the machine must be calibrated. Calibration allows storing the mechanical and electrical parameters specific
to each machine so provide the best balancing results.
13.1 Machine calibration for the CAR/SUV Wheel Type
The calibration for the CAR wheel type and SUV wheel type is the same.
To perform machine calibration, you must first provide for the following material:
A balanced wheel with steel rim that has the following dimensions: diameter from 14” ------16”.
It is not possible to use wheels with aluminum rims.
A 50 grams weight (preferably in Iron or Zinc).
To perform the calibration machine, proceed as follows:
Op.
Description
10
Press [2] or [4] from the keyboard
and select the
icon relative to the programme to be used.
20
Activate the AUTO/SUV calibration programme by selecting
which will
turn green.
30
Confirm activation of the AUTO/SUV calibration programme by pressing [6] on
the keyboard.
40
Remove the wheel and any other accessories from the shaft.
50
Lower the wheel guard: the machine will run a launch.
60
Fit the wheel on the shaft.
Manually enter the wheel dimensions.
If the dimensions of the wheel were introduced before entering the calibration
program, this step can be skipped.
It is not possible to enter the data with the
automatic acquisition system.