STEP 15
( Installation of Motorcycle Adapters )
1. Lower the lift all the way to the ground.
2. Swivel both arms towards the center line of the lift
until they are parallel.
3. Fully extend both arms. (See Fig. 15.1)
4. Align the Motorcycle Adapters and lower onto the lift
arms. Ensure it rests firmly on top of the lift arms. (See Fig.
15.2)
5. Disconnect both cylinder hoses from the Flow Control
Valve. (See Fig. 15.3)
6. Remove steel plug from the lower Flow Control
Valve port. Install the 3/8” x 3/8” Pipe Nipple and Quick
Disconnect fitting into the lower port using Teflon Tape
and tighten. (See Fig. 15.4 / 15.5)
7. Reconnect a single lift hose to the lower quick
disconnect fitting for single column operation. (See Fig.
15.6)
NOTE: During Single Column Operation be sure to
disconnect both Hoses and reconnect only one Hose
assembly to the Lower Port on the Flow Control Valve
or damage to the lift or personnel injury may result.
Fig. 15.2
Fig. 15.1
Fig. 15.3
Fig. 15.6
Fig. 15.5
Fig. 15.4