The   DNA   Pro   Amplifier   system   is   designed   to   be   mounted   in   a   standard   19”   rack   enclosure.   

Where   the   amplifier   is   used   in   a   fixed   installation,   as   long   as   the   bottom   unit   is   supported   and   there   
are   no   gaps   between   units,   it   is   acceptable   to   use   only   the   front   panel   19”   rack   holes   when   fitting   it   
in   a   standard   rack   enclosure.   If   the   amplifier   is   mounted   in   a   mobile   rack   it   is   important   that   the   rear   
is   supported   with   a   rear   rack   mounting   kit   (part   number   ZA1182).   Damage   caused   by   insufficient   
support   is   not   covered   by   the   warranty.   

To   prevent   damage   to   the   front   panel   it   is   recommended   that   plastic   cups   or   washers   are   fitted   
underneath   the   rack   mounting   bolt   heads.   

It   is   possible   to   mount   multiple   DNA   Pro   amplifiers   without   ventilation   gaps   between   them   but   it   is   
essential   that   an   unobstructed   flow   of   clean   air   is   available   from   the   front   of   the   unit   to   the   rear.   It   is   
important   that   neither   the   air   intakes   on   the   front   of   the   unit   or   the   exhaust   vents   at   the   rear   are   
covered.   Steps   must   be   taken   to   ensure   that   hot   air   does   not   continually   circulate   through   the   
amplifiers   from   the   back   of   the   rack   to   the   front.   

The   amplifier   should   never   be   exposed   to   rain   or   moisture   during   operation   or   storage.   If   the   unit   
does   come   into   contact   with   moisture,   remove   the   AC   power   cord   immediately   and   leave   it   in   a   dry   
and   warm   location   to   dry   out.   

Note   that   when   any   equipment   is   taken   from   a   cold   location   into   a   hot   humid   one,   condensation   
may   occur   inside   the   device.   Always   allow   time   for   the   equipment   to   attain   the   same   temperature   as   
its   surrounding   environment   before   connecting   the   AC   power   cord.   

AC   Power   Connection   

The   amplifier   utilises   a   32A   Neutrik   PowerCon

TM

   type   locking   AC   power   connector.   Use   only   an   AC   

power   cord   with   a   correctly   terminated   PowerCon

TM

   type   connector   to   make   the   connection   to   the   

mains   power   supply.   

The   amplifiers   are   designed   to   operate   on   50/60   Hz   AC   power.   The   power   supply   sections   
automatically   configure   themselves   for   either   115V   or   230V   nominal   voltage   at   turn   on.   The   
amplifiers   will   operate   over   an   extended   range   of   supply   voltages   (please   refer   to   the   technical   
specifications).   

Note   that   while   the   amplifier   will   operate   correctly   at   voltages   indicated,   the   specified   output   power   
will   only   be   achieved   when   operating   with   the   stated   nominal   voltages.   

   

   

Summary of Contents for DNA 10K4

Page 1: ...1 Danley Sound Labs DNA Pro Series Advanced System Amplifiers User Guide For DNA 10K4 and DNA 20K4 Version 1 For firmware version 1 100 and above...

Page 2: ...wer Connection 13 The User Guide 14 Introduction and Key Features 15 Introduction 15 Key Features 15 Audio Connections 18 Input Connections 18 Using unbalanced connections 18 Amplifier Output Connecti...

Page 3: ...in and Polarity 28 Delay 29 High and Low pass Filters 29 LIR Crossover Filtering 29 Parametric Equalization and All Pass Filters 29 Limiters 30 Bridge 31 Routing 31 Utility Pages 31 Screen Contrast 31...

Page 4: ...ng 38 Fault Relay 38 Performance Logging 38 Processing Block Diagram 40 Input Menu Map Utility Menu Map 41 Output Menu Map 42 EQ and Filter Response Graphs 43 Technical Specifications 47 General 47 Au...

Page 5: ...ceptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart tripod bracket or table specified by the manufact...

Page 6: ...our remplacer la prise obsol te 10 Prot ger le cordon d alimentation soit cras ou pinc particuli rement au niveau des fiches des prises et le point o ils sortent de l appareil 11 Utilisez uniquement l...

Page 7: ...ouvercles ne desserrez pas les fixations et ne laissez aucune pi ce s introduire dans les ouvertures AVERTISSEMENT DE SECURITE Le radiateur arri re de cet appareil devient chaud Evitez tout contact di...

Page 8: ...nvironments E1 E2 E3 E4 THIS PRODUCT MUST BE EARTHED GROUNDED Use only a flexible cable or cord with a green and yellow core which must be connected to the protective earthing ground terminal of a sui...

Page 9: ...L COMMUNICATIONS COMMISSION NOTICE An example of this equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are d...

Page 10: ...on ou la borne de terre de l installation Le cordon doit tre un maximum de 6 2m de long 14 AWG 2 5mm2 CSA tre class SJ SJT SJE ou 300 500V H05W F et tre marqu e VW 1 THIS PRODUCT IS DESIGNED FOR PERMA...

Page 11: ...fully engineered for world class performance and reliability If you would like further information about this or any other Danley Sound Labs product please contact us We look forward to helping you in...

Page 12: ...12 INSTALLATION INSTRUCTIONS Mechanical Installation 431 360 37 482 88...

Page 13: ...ly circulate through the amplifiers from the back of the rack to the front The amplifier should never be exposed to rain or moisture during operation or storage If the unit does come into contact with...

Page 14: ...know how to drive the front panel A detailed explanation of the front and rear panel controls and indicators is contained in the next section The final section describes each individual function or f...

Page 15: ...nced DSP algorithms using Linea Micro Detail LMD 96kHz sampling frequency provides for a nominally flat response beyond 40kHz Rotary encoders illuminated buttons and graphical display provide a rapid...

Page 16: ...loudspeaker subsystem See Overview of Modules Overlays When the Device is used in Modules view in PodWare this allows the modules to be grouped into Overlay Groups These groups allow various Input mas...

Page 17: ...inear Phase Equalization The Input High Shelf Equalizers use Finite Impulse Response FIR filtering to produce Linear Phase equalization that is all frequencies are delayed by the same amount perfectly...

Page 18: ...ays be connected Pin 1 of the XLR to ensure that EMC performance and regulations are met 2 1 3 Pin 2 HOT Pin 3 COLD Pin 1 Shield Input XLR balanced connection Using unbalanced connections Please note...

Page 19: ...ker1 Speaker2 Speaker2 In addition the channel 1 or channel 3 connector can also be used if the pair of amplifier channels is being operated in bridged mode Amplifier output connections Bridge 2 1 1 2...

Page 20: ...lected channel and parameter information is displayed on the upper part of the screen and the parameter value on the lower part of the screen Status Indicators The OVERLAY indicator shows when there a...

Page 21: ...inal mains voltage of 100V to 230V 50 60Hz without re configuration NOTE The device must be earthed to a suitable power earth failure to do so may affect performance and or operation and will invalida...

Page 22: ...Input A Output 1 Output 2 A Module Preset is a collection of settings parameters for a Drive Module of a particular size The Preset contains a set of parameters for one input and a set of parameters f...

Page 23: ...s which can be thought of as placed on a 2 dimensional grid Horizontally across the width of the grid are the various channels and vertically up and down the grid are the parameter pages for each sect...

Page 24: ...on is then used for control and monitoring of this sub system Drive Module Presets Presets do not change the settings device wide Rather recalling a Module Preset creates a Drive Module by consuming a...

Page 25: ...eset name so they cannot be over written The user can however store an edited version of a Factory Preset in any free preset location In addition to the Factory Presets the device may have further Ske...

Page 26: ...o not disturb parameter Overlays See Overlays A RECL Preset Name SUBS 40 2 X 18 BASS Recalling Components To recall a Component Preset to a single output press the OUTPUT button then use the down q bu...

Page 27: ...stream For other details on the operation of the Digital Audio Network please refer to the relevant manufacturer s documentation Gain and Polarity The gain page of the input channel selected allows u...

Page 28: ...pletely removed by setting the enable parameter to the Off position Note that this EQ can only be used in Module Groups if set to On Also see Latency Delay Parametric Filters Parametric filters are de...

Page 29: ...out the complications and disadvantages inherent with the FIR technique The shape of the LIR crossover filter is similar to a 4th order Linkwitz Riley filter and maintains zero phase difference betwee...

Page 30: ...ncy used in the crossover filters in a given Drive Module In VX mode the delay is related to the Split frequency This delay will be applied to all of the outputs in a given Drive Module to keep them i...

Page 31: ...nnels since both of the amplifiers in the pair are driven with the same signals as determined by the channel 1 or channel 3 controls Bridge settings should be set up before recalling Drive Module Pres...

Page 32: ...n either Octaves or Q Aux Style This page of the UTILITY menu allows the action of the Aux port to be viewed and adjusted Also see Aux Port ECO This page of the UTILITY menu allows the device to save...

Page 33: ...an office where there is a DHCP server both the computer and the Device will be in the DHCP IP address range and so will connect immediately AUTO IP The device will initially search for a DHCP server...

Page 34: ...to be concerned about what parameters might have been saved in users Snapshots It does however require that any existing edits to the parameters in Drive Modules are stored into Drive Module presets b...

Page 35: ...nd Gnd Mute Recall Snapshot 3 Recall Snapshot 4 Mute Some of the above modes allow the AUX Port to be used either in Event mode whereby a momentary push button or momentary relay contact closure on on...

Page 36: ...cy figure is calculated using the crossover High pass frequency in kHz This latency figure is calculated using the Vx Split frequency in kHz Important tip The processing latency is constant at 1 53ms...

Page 37: ...button for 5 seconds When in secure mode this will be shown on the display Note that the Ethernet communications port is still active in secure mode Overlay Flush If the device has been used in Module...

Page 38: ...cting Enable Disable Alarms Doing this will show a cross over the Incident indicator and the device will no longer report any Incidents at this level or below If any Incidents have previously been dis...

Page 39: ...t itself from potential damage The data in the log can be exported by right clicking on the log to launch a context menu and selecting copy log data to clipboard The data could then be pasted into a s...

Page 40: ...40 Processing Block Diagram...

Page 41: ...SNAP CH B CH C CH A CH D FIR FIR FIR FIR EQ6 EQ6 EQ6 EQ6 EQ5 EQ5 EQ5 EQ5 EQ4 EQ4 EQ4 EQ4 EQ3 EQ3 EQ3 EQ3 EQ 2 EQ 2 EQ 2 EQ 2 EQ 1 EQ 1 EQ 1 EQ 1 EQb EQb EQb EQb EQa EQa EQa EQa HPF HPF HPF HPF DEL DEL...

Page 42: ...EQ 3 EQ 2 EQ 2 EQ 2 EQ 2 EQ 1 EQ 1 EQ 1 EQ 1 EQ EQ EQ EQ LPF LPF LPF LPF HPF HPF HPF HPF DEL DEL DEL DEL GAIN GAIN GAIN OUT GAIN RECL RECL RECL RECL ROUT ROUT ROUT ROUT LIM LIM LIM LIM TMAX TMAX TMAX...

Page 43: ...43 EQ and Filter Response Graphs...

Page 44: ...44...

Page 45: ...45...

Page 46: ...46...

Page 47: ...annel all channels driven with continuous program material at a crest factor of 2 8 9dB 20K4 2600W RMS into 4 Ohms 5200W RMS into 8 Ohms bridged 10K4 1300W RMS into 4 Ohms 2600W RMS into 8 Ohms bridge...

Page 48: ...ries Resonant Topology auxiliary and standby supplies Low quiescent Eco Flyback Internally stored energy 600 Joules Mains input voltage range automatically configured 85V to 240V Mains input frequency...

Page 49: ...network or the Volt free changeover relay contacts accessibly on the rear panel Physical Cooling Variable speed fans Airflow Front to back Air filtration Washable media changeable without the use of t...

Reviews: