P
I
02 9604 1226 E
I
|
danielaappliances.com.au
PA G E 1 9
TROUBLESHOOTING
• USERS ARE NOT ALLOWED TO PERFORM ANY MAINTENANCE
OPERATIONS ON ANY PARTS OF THIS APPLIANCE.
• MAINTENANCE MUST BE CARRIED OUT EXCLUSIVELY BY AUTHORIZED
TECHNICAL SERVICE PERSONNEL.
To access burners, injectors, valves etc; disconnect gas and power supply from appliance.
Ensure appliance is cool before removing trivets, burners etc.
When you need to access under hob, remove screws which hold the hob in position, located
under each burner. Lift hob to access valves and electrical system.
To re-assemble, carry out work in reverse order, and test operation of appliance before leaving.
TROUBLE
POSSIBLE CAUSE
SOLUTION
FOR THE USER
FOR THE TECHNICAL
SUPPORT SERVICE
Burner won't light.
Gas and electrical supply
not working.
Check the gas supply
is turned on. Also
ensure electrical
supply is operational.
Test gas pressure
and electrical supply
is correct. Turn on if
necessary.
Pressure drop in gas pipe
Check appliance inlet
supply, pipe sizes,
contact the gas utility
company.
The ignition plug is not
securely fixed, or the
connection with the
cable is wrong.
Check the
connection.
Gas valve damaged.
Replace it.
After releasing the
knob, the flame
goes out.
The thermocouple is not
burner flame.
Clean and reapet the
ignition procedure.
Clean burner
assembly.
Thermocouple faulty.
Replace the
thermocouple.
Gas valve faulty.
Replace it.