Shop/Work Table Mounting
The following method of mounting your Coll-O-Crimp equipment package
is offered as a guide and may be varied to suit your particular needs.
1.
Open shipping cartons and remove all equipment and components.
2.
Prepare mounting surface for Coll-O-Crimp press and power unit.
Refer to Figure 1 for bolt hole layout and optimum working height.
IMPORTANT - Care must be taken to insure that the surface to which
the press is bolted is capable of supporting the weight of the press
(approximately 113 lbs.) which extends 8-5/8” over the front edge of the
mounting surface.
3.
Bolt T-421 U press to the mounting surface.
4.
Place power unit on mounting surface adjacent to the T-421 U press
within convenient working distance.
5.
Remove plug from middle port on top of press.
6.
Locate press/pump connecting hose assembly and remove 4315X6X8
For-Seal adapter from hose assembly. Thread into port on press (from
Step 5) and tighten.
7.
See page 5 (step 7) for appropriate connecting port.
8. ELECTRIC PUMP (T-421U):
Remove 4205X6X8 For-Seal adapterfrom
hose assembly (T-400-16) and thread into the top middle port of
pump. Connect hose assembly to pump and press.